1 Pt100 KN 1515
The KN Series Ceramic Wire Wound PRTDs are suitable for
general applications requiring temperature stability.
Applications: Industrial resistance thermometers, especially
in chemical, power generation plants and analytical
equipment.
Construction: A platinum coil is sealed inside a high purity
aluminum oxide ceramic body. Lead wires are shear force
resistant and assure proper connection to extension leads
and cables.
Models
1Pt100 KN 1515
32.206.456
32.206.457
W0.15
W0.1
0.08
15
+2
- 0
10.0±0.5
1.5±0.15 0.20±0.01
Temperature stability:
Excellent long-term stability
Tolerance class:
Also available:
Temperature range:
Temperature
coefficient:
Tc = 3850 ppm/K
Leads:
Palladium-gold alloy
Measuring current:
1 mA
Insulation resistance
after assembly:
> 100 MOhm @ 25 °C
Nominal resistance:
100 Ohm @ 0 °C
W0.3 (Class B) = -196 to +660 °C
W0.15 (Class A) = -196 to +600 °C
(Heraeus exceeds IEC 60751: -100 to +450 °C)
W0.1 (Class 1/3 B) = -100 to +350 °C
W0.03 (Class 1/10 B) = -50 to +300 ºC
(Special HST Class proportional to W0.3)
- According to IEC 60751:2008
- Other standards and narrower
tolerances are available on request
- Platinum-gold alloy
- Different temperature coefficients
(3916 ppm/K - old JIS)
- Extension leads
- Two separated coils can be embedded
in one ceramic body
The measuring point is located at 8 mm from the end of the sensor body
W0.03
32.206.112
Models
Technical Specification
0.2
0.4
15.7
5.0
1Pt100 KN 1515 G
32.206.901
32.206.902
32.206.903
W0.3
W0.15
W0.1
0.08
15
+2
- 0
10.0±0.5
1.5±0.15 0.27±0.01
0.2
0.4
15.7
5.0
Status 01/2009. Technical modifications reserved.
Self Heating
0°C (K/mW)
Water current
V=0.4m/s
Air stream
V=3m/s
t
0.5
t
0.9
t
0.9
t
0.5
Description
Tolerance
IEC 60751
Order No.
Dimensions
mm
L
D
d
l
Response time
32.206.455
W0.3
Heraeus Sensor Technology USA
Status: HSTUSA 06/16
770 Township Line Road, Suite 300
Yardley, PA 19067 USA
Phone 1-215-944-9010 Fax 1-215-944-9392
Email info.hst-us@heraeus.com
www.hst-us.com