AD8421-EP Enhanced Product
Rev. 0 | Page 6 of 20
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter Rating
Supply Voltage ±18 V
Output Short-Circuit Current Duration Indefinite
Maximum Voltage at −IN or +IN
1
−V
S
+ 40 V
Minimum Voltage at −IN or +IN +V
S
− 40 V
Maximum Voltage at REF
2
+V
S
+ 0.3 V
Minimum Voltage at REF −V
S
− 0.3 V
Storage Temperature Range −65°C to +150°C
Operating Temperature Range
Maximum Junction Temperature 150°C
ESD
Human Body Model 2 kV
Charged Device Model 1.25 kV
1
For voltages beyond these limits, use input protection resistors. See the
AD8421 data sheet for more information.
2
There are ESD protection diodes from the reference input to each supply, so
REF cannot be driven beyond the supplies in the same way that +IN and −IN
can. See the AD8421 data sheet for more information.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
THERMAL RESISTANCE
θ
JA
is specified for a device in free air using a 4-layer JEDEC
printed circuit board (PCB).
Table 3.
Package θ
JA
Unit
8-Lead MSOP 138.6 °C/W
ESD CAUTION