SUB-GROUP C1 COMBINED SAMPLE
OF SPECIMENS OF SUB-GROUPS
C1A AND C1B
D
4.11.6 Final measurements Visual examination No visible damage
Legible marking
Capacitance |C/C| 5 % of the value measured in
4.11.1.
Tangent of loss angle Increase of tan :
0.008
Compared to values measured in 4.11.1.
Voltage proof
2250 V
DC
; 1 min between term.
No permanent breakdown or flash-over
Insulation resistance 50 % of values specified in section
“Insulation resistance” of this
specification
SUB-GROUP C2 D
4.12 Damp heat steady state 56 days, 40 °C, 90 % to 95 % RH no load
capacitance
4.12.1 Initial measurements Capacitance
Tangent of loss angle at 10 kHz
4.12.3 Final measurements Visual examination No visible damage
Legible marking
Capacitance |C/C| 5 % of the value measured in
4.12.1.
Tangent of loss angle Increase of tan :
0.007
Compared to values measured in 4.12.1.
Voltage proof
2250 V
DC
; 1 min between term.
No permanent breakdown or flash-over
Insulation resistance 50 % of values specified in section
“Insulation resistance” of this
specification
SUB-GROUP C3 D
4.13.1 Initial measurements Capacitance
Tangent of loss angle at 10 kHz
4.13 Impulse voltage 3 successive impulses, full wave, peak
voltage:
5 kV
Max. 24 pulses
No selfhealing breakdowns or flashover
4.14 Endurance Duration: 1000 h
1.7 U
RAC
at 105 °C
Once in every hour the voltage is
increased to 1000 V
RMS
for 0.1 s via
resistor of 47 ± 5 %
GROUP C INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST
D
OR
ND