SAC-5P-M12MS/ 0,3-802/M12FR-3L Order No.: 1457306
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1457306
PHOENIX CONTACT Inc., USA Page 2 / 5
http://www.phoenixcon.com May 6, 2011
Insulation resistance ≥ 100 MΩ
Length of cable 0.3 m
Ambient temperature (operation) -25 °C ... 90 °C (Male connector / female connector)
General characteristics
Standards/regulations M12 connector IEC 61076-2-101
Coding A - standard
Surge voltage category II
Pollution degree 3
Degree of protection IP65/IP68/IP69K
Insertion/withdrawal cycles ≥ 100
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material TPU GF
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, (nickel-plated)
Sealing material NBR
Status display 3 LEDs
Conductor data
Cable type PUR halogen-free, highly flexible, resistant to welding beads,
gray
Cable type (abbreviation) 802
Cable abbreviation Li12Y11Y-HF
Conductor cross section 0.34 mm²
AWG signal line 22
Conductor structure signal line 42x 0.10 mm
Core diameter including insulation 1.3 mm ±0.05 mm
External cable diameter 5.1 mm ±0.2 mm
Wire colors Black, brown, blue, white, green/yellow
External sheath, color Gray RAL 7001
Insulation resistance min. 20 MΩ*km
Conductor resistance Approx. 53 Ω/km
Nominal voltage, conductor 300 V
Test voltage, conductor 1200 V
Overall twist 5 wires around filler to the core
Outer sheath, material PUR