http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TMV-HI Series 1 Watt
Input Specifications
Input current no load 5 Vin models: 35 mA typ.
12 Vin models: 17 mA typ.
15 Vin models: 16 mA typ.
24 Vin models: 12 mA typ.
Surge voltage (1 s max.) 5 Vin models: 9 V max.
12 Vin models: 18 V max.
15 Vin models: 20 V max.
24 Vin models: 30 V max.
Input filter internal capacitor
Internal power dissipation 450 mW max.
Recommended input fuse (slow blow) 5 Vin models: 500 mA
12 Vin models: 200 mA
15 Vin models: 150 mA
24 Vin models: 100 mA
Output Specifications
Voltage set accuracy ±5 % max.
Voltage balance (dual output models, balanced loads) 0.1% typ. / 1 % max.
Regulation – Input variation (1 % change Vin) 1.2 % typ.
– Load variation (20 – 100 %) 3.3 VDC models: <20 %
5 VDC models: <15 %
other models: <10 %
Ripple and noise (20 MHz Bandwidth) 100 mVp-p max.
Temperature coefficient ±0.01 %/K typ. / ±0.02 %/K max.
Short circuit protection continuous, automatic recovery
Capacitive load –Single output 3.3 VDC models: 1000 µF max.
5.0 & 9.0 VDC models: 470 µF max.
12 & 15 VDC models: 220 µF max.
–Dual output ±5.0 & ±9.0 VDC models: 220 µF max. (each output)
±12 & ±15 VDC models: 100 µF max. (each output)
+15 / –9 VDC models: 100 / 220 µF max.
Isolation /Safety
Isolation voltage – Isolation test voltage (tested for 1 s) 5‘700 Vpk
– I/O isolation voltage (60 s) 5’200 VDC
Isolation capacitance (input/output) 7 pF typ.
Isolation resistance (input/output) >10 Gohm
Common mode transient immunity (dv/dt) 15 kV/µs min.
General Specifications
Temperature ranges – Operating (natural convection) –40°C to +95°C
– Case temperature +100°C max.
Power derating 6.7 %/K above +85°C
Humidity (non condensing) 95 % rel H max.
Altitude during operation 4000 m
Switching frequency 100 kHz typ. (frequency modulation)
Safety standards CAN/CSA-C22.2 No 60950-1-07, 2nd ed; A1:2011
ANSI/UL No. 60950-1, 2nd ed.; A1:2011
IEC 60950-1:2005 (2nd edition); Am 1:2009
EN 60950-1:2006/A11:2009/A1:2010/A12:2011
– Certification documents www.tracopower.com/overview/tmv-hi
Environmental compliance – Reach
www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU