4130-G211-K4M1-20A

High Performance Thermal Circuit Breaker 4130-...
www.e-t-a.de
1646
1
1
Description
Typical applications
Ordering information
Approvals
Technical data
Single pole high performance thermal circuit breaker, with push-to-reset
tease free, trip-free snap action mechanism (R-type TO CBE to EN
60934). Designed for threadneck panel mounting and for applications
with a high fault current switching requirement.
Approved to CBE standard EN 60934 (IEC 60934).
US patent number: US 6,040,747
Motors, transformers, solenoids, battery chargers, power supplies,
appliances, machinery, extra low voltage systems.
4130-...
Standard current ratings and typical internal resistance values
Type No.
4130 single pole thermal circuit breaker
Mounting
G2 M12x1, knurled nut (bulk shipped with 5 pcs plus)
G4 M12x1, hex nut and knurled nut (bulk shipped with 5 pcs plus)
Number of poles
1 single pole, thermally protected
Actuator configuration
1 black push button
Terminal design
K4 terminal M6x8
screw and washer bulk shipped
Characteristic curve
M1 medium delay
Current ratings
20... 80 A
4130 - G2 1 1 - K4 M1 - 20 A ordering example
For further details please see chapter: Technical Information
Voltage rating AC 240 V; DC 50 V
Current rating range 20...80 A
Typical life
AC 240 V: 20...70 A 100 operations at 2 x I
N
, inductive
500 operations at 2 x I
N
, resistive
DC 50 V: 20...80 A 500 operations at 2 x I
N
, inductive
Ambient temperature -30...+60 °C (-22...+140 °F)
Insulation co-ordination rated impulse pollution
(IEC 60664) withstand voltage degree
2.5 kV 2
(reinforced insulation in the mounting area)
Dielectric strength
operating area test voltage
AC 3,000 V
Insulation resistance > 100 MΩ (DC 500 V)
Interrupting capacity I
cn
800 A
Interrupting capacity
(UL 1077) I
N
U
N
20...80 A AC 240 V 1,000 A
20...60 A AC 120 V 3,500 A
80 A AC 120 V 2,000 A
20...50 A DC 50 V 3,500 A
60...80 A DC 50 V 2,000 A
Degree of protection operating area IP40
(IEC 60529/DIN 40050) terminal area IP00
Vibration 8 g (57-500 Hz) ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock 25 g (11 ms)
to IEC 60068-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass approx. 55 g
Current
rating (A)
Internal
resistance (Ω)
Current
rating (A)
Internal
resistance (Ω)
20 < 0.02 40 < 0.01
25 < 0.02 50 < 0.01
30 < 0.02 60 < 0.01
35 < 0.02 70 < 0.01
35 < 0,02 80 < 0,01
Preferred types
Preferred types Standard current ratings (A)
20 25 30 35 40 45 50 60 70 80
4130-G211-K4M1-
x x x x x x x x x
4130-G411-K4M1-
x x x x x x x x x
Authority Standard Rated voltage Current ratings
VDE IEC/EN 60934 AC 240 V
DC 50 V
20 A…70 A
20 A…80 A
UL UL 1077 AC 240 V
DC 50 V
20 A…80 A
20 A…80 A
CSA C22.2 No 235 AC 240 V
DC 50 V
20 A…80 A
20 A…80 A
High Performance Thermal Circuit Breaker 4130-...
www.e-t-a.de
1646
2
1
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also section
Technical information.
Ambient temp. °F
°C
-22
-30
-4
-20
+14
-10
+32
0
+73.4
+23
+104
+40
+122
+50
+140
+60
Derating factor
0.68 0.76 0.84 0.92 1 1.08 1.16 1.24
Dimensions
Accessories
22.3
LINE
tightening torque max. 1.5 Nm
M12x1
black
OFF
ON
23.8
±0.5
17.2±0.5
50
0.6
±0.2
10.3
64
2
I
13.5
max. 3.5
screw M6x8 with washer
tightening torque max. 2.5 Nm
ø6.6
12
17
32
18
D-shaped threadneck
12.2-0.1
mounting hole
11.5
-0.1
1.26
.453
-.004
.709
.480
-.004
.472
.669
.531
.878
max .138
.260
.024±.008
.4062.52
.937
±.020
.677±.020
1.97
12468102040
... times rated current
Trip time in seconds
10000
1000
100
10
1
0,1
350,8
23 °C
60 °C
-30 °C
Typical time/current characteristics
LINE
2
I
operating area
30
6
mounting area
5
1.18 .236
.197
Intstallation drawing
2
line 1
Internal connection diagram
Separate hardware
Hex nut Y 300 116 02
Hex nut with splash cover, black
X
201 296 01 without O ring (IP64)
X
200 801 03 with O ring (IP66 /IP67)
Hex nut with splash cover,
transparent
X
200 801 08 with O ring (IP66/IP67)
M12x1
M12x1
Water splash cover,
transparent with knurled
nut and O ring (IP64)
X 210 663 01
M12x1
2.5
Knurled nut
Y 302 065 01
ø17
M12x1
3.2
0.5 x 45°
SW14
.551
.098
.126
.669
.020 x 45°
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.

4130-G211-K4M1-20A

Mfr. #:
Manufacturer:
E-T-A Circuit Breakers
Description:
Circuit Breakers
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union