MC74LV594A
www.onsemi.com
5
MAXIMUM RATINGS
Symbol Parameter Value Unit
V
CC
DC Supply Voltage −0.5 to +7.0 V
V
I
DC Input Voltage −0.5 to V
CC
+ 0.5 V
V
O
DC Output Voltage Active Mode (Note 1) −0.5 to V
CC
+ 0.5 V
High Impedance or Power−Off Mode −0.5 to +7.0
I
IK
DC Input Clamp Current ±20 mA
I
OK
DC Output Clamp Current ±35 mA
I
IN
DC Input Current ±20 mA
I
O
DC Output Source / Sink Current ±35 mA
I
CC
DC Supply Current per Supply Pin ±75 mA
I
GND
DC Ground Current per Ground Pin ±75 mA
T
STG
Storage Temperature Range −65 to +150 °C
T
L
Lead temperature, 1 mm from Case for 10 Seconds 260 °C
T
J
Junction temperature under Bias +150 °C
q
JA
Thermal Resistance SOIC
TSSOP
112
148
°C
P
D
Power Dissipation in Still Air at SOIC
TSSOP
500
450
mW
MSL Moisture Sensitivity Level 1
F
R
Flammability Rating Oxygen Index: 30% − 35% UL−94−VO (0.125 in)
V
ESD
ESD Withstand Voltage Human Body Model (Note 2)
Machine Model (Note 3)
Charged Device Model (Note 4)
> 3000
>400
N/A
V
I
Latchup
Latchup Performance Above V
CC
and Below GND at 85°C (Note 5) ±300 mA
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. I
O
absolute maximum rating must be observed.
2. Tested to EIA/JESD22−A114−A.
3. Tested to EIA/JESD22−A115−A.
4. Tested to JESD22−C101−A.
5. Tested to EIA/JESD78.
RECOMMENDED OPERATING CONDITIONS (Note 6)
Symbol Parameter Min Max Unit
V
CC
DC Supply Voltage (Referenced to GND) 2.0 6.0 V
V
I
DC Input Voltage (Referenced to GND) 0 V
CC
V
V
O
DC Output Voltage (Referenced to GND) 0 V
CC
V
T
A
Operating Free−Air Temperature −55 +125 °C
t
r
, t
f
Input Rise or Fall Rate V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
0
0
0
1000
500
400
nS
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
6. All unused inputs of the device must be held at V