Insulation and Safety Related Specications
Parameter Symbol HCPL-J314 Units Conditions
Minimum External Air Gap L(101) 7.4 mm Measured from input terminals to output
(Clearance) terminals, shortest distance through air.
Minimum External Tracking L(102) 8.0 mm Measured from input terminals to output
(Creepage) terminals, shortest distance path along body.
Minimum Internal Plastic Gap 0.5 mm Through insulation distance conductor to
(Internal Clearance) conductor, usually the straight line distance
thickness between the emitter and detector.
Tracking Resistance CTI >175 V DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking Index)
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units Note
Storage Temperature T
S
-55 125 °C
Operating Temperature T
A
-40 100 °C
Average Input Current I
F(AVG)
25 mA 1
Peak Transient Input Current I
F(TRAN)
1.0 A
(<1 µs pulse width, 300pps)
Reverse Input Voltage V
R
5 V
“High” Peak Output Current I
OH(PEAK)
0.6 A 2
“Low” Peak Output Current I
OL(PEAK)
0.6 A 2
Supply Voltage V
CC
- V
EE
-0.5 35 V
Output Voltage V
O(PEAK)
-0.5 V
CC
V
Output Power Dissipation P
O
260 mW 3
Input Power Dissipation P
I
105 mW 4
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reow Temperature Prole See Package Outline Drawings section