1
Sensing distance
Supply voltage
Output
100/200 mA
NPN or PNP
12 to 24 VDC
1.5mm
3 mm
5 mm
5 mm20 mm
Inductive Proximity Sensor
TL-W/WM
Space Saving Flat Proximity Switch
Space-saving, low-profile rigid aluminum die-cast
housing (TL-W5E/F).
All models provided with an operation indicator.
Mounting
possible from either the front or
rear of the
housing.
Protected to endure water and oil splashes
(conforms to IEC IP67).
DC 2-wire models (TL-W5MD1/-W5MD2) provide
easy wiring.
Ordering Information
DC 2-wire
Sensing
head
Sensing distance
Output
NPN PNP
NO NC NO NC
Non-shielded
5 mm
TL-W5MD1 TL-W5MD2 --- ---
DC 3-wire
Sensing
head
Sensing distance
Output
NPN PNP
NO NC NO NC
Shielded
5 mm
TL-W5E1 TL-W5E2 TL-W5F1 TL-W5F2
Non-shielded
1.5 mm
TL-W1R5MC1 --- TL-W1R5MB1 ---
3 mm
TL-W3MC1 TL-W3MC2 TL-W3MB1 TL-W3MB2
5 mm
TL-W5MC1 TL-W5MC2 TL-W5MB1 ---
20 mm
TL-W20ME1 TL-W20ME2 --- ---
TL-W/WM
TL-W/WM
2
Application Examples
Position
of W
orkpiece
Specifications
Ratings/Characteristics
DC 2-wire
Item TL-W5MD
Sensing
distance
5 mm
±10%
Supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC)
Current consumption
(leakage current)
0.8 mA max.
Sensing object
Magnetic metals (refer to
“Engineering Data”
for non-magnetic metals)
Setting distance
(standard sensing object)
0 to 4 mm (iron, 18 x 18 x 1 mm)
Differential travel
10% max. of sensing distance
Response frequency
(see note)
0.5 kHz
Operating mode (for detecting
sensing objects)
D1 models:
Load ON
D2 models: Load OFF
Control output
(switching capacity)
3 to 100 mA DC
Circuit protection
Load short-circuit protection
Indicator
D1 models:
Operation indicator (red LED), operation set indicator (green LED)
D2 models: Operation indicator (red LED)
Ambient temperature
Operating: –25
°
C to 70
°
C (with no icing)
Ambient humidity
Operating: 35% to 95%
T
emperature influence
±
10% max. of sensing distance at 23
°
C in temperature range of –25
°
C to 70
°C
V
oltage influence
±
2.5% max. of sensing distance in rated voltage range
±15%
Residual voltage
3.3 V max. (with 100 mA load current and 2-m cable)
Insulation resistance
50 M
min. (at 500 VDC) between current carry parts and case
Dielectric strength
1,000 V
AC for 1 min between current carry parts and case
V
ibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y
, and Z directions
Shock resistance
Destruction: 500 m/s
2
(approx. 50G) for 3 times each in X, Y
, and Z directions
Enclosure ratings
IEC IP67 (JEM IP67G (water-tight, oil-tight)
W
eight (with 2-m cable)
Approx. 45 g
Material Case Heat-resistive ABS resin
Sensing surface
Note:
The response frequency in the table is a mean value obtained under the following conditions.
Location of each standard sensing object: At a distance half as long as the sensing distance of the sensor
.
Distance between any two adjacent standard sensing objects: T
wice as wide as the width of the standard sensing object.
TL-W/WM
TL-W/WM
3
DC 3-wire
Item TL-W1R5M TL-W3M TL-W5M TL-W5 TL-W20M
Sensing
distance
1.5 mm
±10%
3 mm
±10%
5 mm
±10%
20 mm
±10%
Supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
12 to 24 VDC (10 to
30 VDC), ripple
(p-p): 20% max.
12 to 24 VDC (10 to
30 VDC)
Current consumption
(leakage current)
15 mA max. at 24 VDC (no-load) 10 mA max.
15 mA max. at
24 VDC (no-load)
8 mA at 12 VDC,
15 mA at 24 VDC
Sensing object
Magnetic metals (Non-magnetic metals can be detected if they are located close to the sensor
. Refer to
“Engineering Data”
for details)
Setting distance
(standard sensing
object)
0 to 1.2 mm (iron,
8 x 8 x 1 mm)
0 to 2.4 mm (iron,
12 x 12 x 1 mm)
0 to 4 mm (iron, 18 x 18 x 1 mm)
0 to 16 mm (iron, 50
x 50 x 1 mm)
Differential travel
10% max. of sensing distance
1% to 15% of
sensing distance
Response frequency
(see note)
1 kHz
600 Hz min. 500 Hz min. 300 Hz min.
40 Hz
Operating mode (for
detecting sensing
objects)
Load ON
E1 models: Output signal low
, load ON
E2 models:
Output signal high, load OFF
F1 models: Output signal high, load ON
F2 models:
Output signal low, load OFF
Control output
(switching capacity)
NPN or PNP open collector
, 100 mA
max.
NPN or PNP open
collector
, 50 mA
max. at 12 VDC,
100 mA max. at 24
VDC
200 mA max.
100 mA max. at
12 VDC,
200 mA max. at
24 VDC
Circuit protection
Reverse connection protection
---
Ambient temperature
Operating: –25
°
C to 70
°
C (with no icing)
Ambient humidity
Operating: 35% to 95%
T
emperature influence
±
10% max. of sensing distance at 23
°
C in temperature range of –25
°
C to 70
°C
V
oltage influence
±
2.5% max. of sensing distance in
rated voltage range
±10%
±
2.5% max. of
sensing distance in
rated voltage range
±20%
±
2.5% max. of sensing distance in rated
voltage range
±10%
Residual voltage
1.0 V max. (with 100 mA load current
and 2-m cable)
1.0 V max. (with
50 mA load current
and 2-m cable)
2.0 V max. (with
200 mA load current
and 2-m cable)
1.0 V max. (with
200 mA load current
and 2-m cable)
Insulation resistance
50 M
min. (at 500 VDC) between current carry parts and case
Dielectric strength
1,000 V
AC, 50/60 Hz for 1 min between current carry parts and case
V
ibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y
, and Z directions
Shock resistance
Destruction: 500 m/s
2
(approx. 50G) for 3 times each in X, Y
, and Z directions
Destruction:
500 m/s
2
(approx.
50G) for 10 times
each in X, Y
, and Z
directions
Enclosure ratings
IEC IP67 (JEM IP67G (water-tight, oil-tight)
W
eight (with 2-m cable)
Approx. 30 g Approx. 45 g Approx. 70 g
Approx. 180 g
Material Case ABS resin ADC (Al die-cast) Heat-resistive ABS
Sensing
surface
ABS resin

TL-W5MB1

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Proximity Sensors INDUCTIVE PNP-NO
Lifecycle: