86
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
V and W Series
Multipurpose Power Line RFI Filter for Emission Control
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz: .5 mA
@250 VAC 50 Hz: .82 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 to 20A*
Operating Ambient Temperature Range
(at rated current I
r
): -10°C to +40°C
In an ambient temperature (T
a
)
higher than +40°C
the maximum operating current (I
o
) is calculated as
follows: I
o
= I
r
(85-Ta)/45
• Offers an N = 3 (“T”) Line to Ground impedance to
common mode and an N = 5 “Dbl. Pi”) impedance
for Line to Line differential mode interference
• Designed for susceptibility use when equipment
impedance at RF frequencies is low
Ordering Information
20 V V 6
Input / Output Style
1 – .250 [6.3] spade terminals
6 – Threaded bolt
7 – IEC inlet*
(line side)
.250 [6.3] spade terminals
(load side)
V or W Series
Leakage current designation
V – Standard
C
urrent Rating
3, 6, 10 or 20A
Specifications
UL Recognized
CSA Certified
VDE Approved
VV6 / VW6
*IEC 60320-1 C20 inlet mates with C19 connector
VV1 / VW1
Electrical Schematics
V Series
W Series (3, 6 & 10A)
W Series (20A)
W Series
• Offers an N = 4 (“Dbl. L”) Line to Ground
impedance for common mode and an N=5 (“Dbl.
Pi”) impedance for Line to Line differential mode
interference
• Designed for use when equipment impedance at
RF frequencies is high
• Two stage construction provides excellent
suppression at high frequencies
V Series
20VW7, 20A model tested by Underwriters Laboratories
to US and Canadian requirements and is
VDE approved at 16A, 250VAC
Both the V and W series are effective to control
emissions in equipment using SCR and T
2
L circuits
for compliance with FCC Part 15, Subpart J and
EN55022, Level A, down to 150kHz