PF (APF)
–3–
ASCTB205E 201612-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “Usage, transport and storage
conditions” in NOTES.
3. Electrical life
Condition: Resistive load, at 6 times/min.
Characteristic Item Specifications
Contact
Arrangement 1 Form A 1 Form C
Contact resistance (Initial) Max. 100 mΩ (AgNi type), Max. 30 mΩ (AgNi type/Au-plated) (By voltage drop 6 V DC 1A)
Contact material AgNi type, AgNi type/Au-plated
Rating
Nominal switching capacity (resistive load) 6 A 250 V AC
Max. switching power (resistive load) 1,500 VA
Max. switching voltage 250V AC
Max. switching current 6 A (AC)
Min. switching capacity (Reference value)*
1
100 mA 5 V DC (AgNi type), 1 mA 1 V DC (AgNi type/Au-plated)
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
6,000 V
Operate time (at 20°C 68°F)
Max. 8 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20°C 68°F)
Max. 4 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance
Functional
Min. 98 m/s
2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10μs)
Min. 49 m/s
2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10μs)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 11 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical Min. 5×10
6
(at 180 times/min.)
Conditions Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 5 g .18 oz
Type Switching capacity No. of operations
1 Form A 6A 250V AC min. 5×10
4
1 Form C
N.O.
6A 250V AC
min. 5×10
4
N.C. min. 3×10
4