HIH-4010/4020/4021 Series
2 www.honeywell.com/sensing
TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
Parameter Minimum Typical Maximum Unit Specific
Note
Interchangeability (first order curve)
– – – – –
0% RH to 59% RH -5
–
5 % RH
–
60% RH to 100% RH -8
–
8 % RH
–
Accuracy (best fit straight line)
-3.5 – +3.5
% RH 1
Hysterisis
–
3
–
% RH
–
Repeatability
–
±0.5
–
% RH
–
Settling time
– –
70 ms
–
Response time (1/e in slow moving air)
–
5
–
s
–
Stability (at 50 %RH in 1 year)
–
±1.2
–
% RH 2
Stability (at 50 %RH in 1 year)
–
±0.5
–
% RH 3
Voltage supply 4
–
5.8 Vdc 4
Current supply
– 200
500 µA
–
Voltage output (1
st
order curve fit) V
OUT
=(V
SUPPLY
)(0.0062(sensor RH) + 0.16), typical at 25 ºC
Temperature compensation True RH = (Sensor RH)/(1.0546 – 0.00216T), T in ºC
Output voltage temp. coefficient at 50% RH, 5 V
– -4 –
mV/ºC
–
Operating temperature -40[-40] See Figure 1. 85[185] ºC[ºF]
–
Operating humidity (HIH-4010) 0 See Figure 1. 100 % RH
5
Operating humidity (HIH-4020) 0 See Figure 1. 100 % RH
5
Operating humidity (HIH-4021) 0 See Figure 1. 100 % RH
–
Storage temperature -50[-58]
–
125[257] ºC[ºF]
–
Storage humidity See Figure 2. % RH
5
Specific Notes:
1. For HIH-4010/20/21-003/004 catalog listings only.
2. Includes testing outside of recommended operating zone.
3. Includes testing for recommended operating zone only.
4. Device is calibrated at 5 Vdc and 25 ºC.
5. Non-condensing environment. When liquid water falls on the
humidity sensor die, output goes to a low rail condition
indicating no humidity.
General Notes:
• Sensor is ratiometric to supply voltage.
• Extended exposure to >90% RH causes a reversible
shift of 3% RH.
• Sensor is light sensitive. For best performance, shield
sensor from bright light.
FACTORY CALIBRATION DATA
HIH-4010/4020/4021 Sensors may be ordered with a
calibration and data printout. See Table 2 and the order guide
on the back page.
TABLE 2. EXAMPLE DATA PRINTOUT
Model HIH-4010-003
Channel 92
Wafer 030996M
MRP 337313
Calculated values at 5 V
V
OUT
at 0% RH
V
OUT
at 75.3% RH
0.958 V
3.268 V
Linear output for 3.5% RH
accuracy at 25 °C
Zero offset
Slope
Sensor RH
0.958 V
30.680 mV/%RH
(V
OUT
- zero offset)/slope
(V
OUT
- 0.958)/0.0307
Ratiometric response for
0% RH to 100% RH
V
OUT
V
SUPPLY
(0.1915 to 0.8130)
For HIH-4010-001/002/003/004 catalog listings only.
For HIH-4020-001/002/003/004 and HIH-4021-001/002/003/
004 catalog listings only.