3
Absolute Maximum Ratings @ T
A
= 25 °C
Parameter White Unit
Power Dissipation Per Segment 39 mW
Peak Forward Current Per Segment
(1/10 Duty Cycle., 0.1 ms pulse width)
80 mA
Continuous Forward Current Per Segment
Derating Linearly From 25 °C Per Segment
10 mA
0.083 Z
Reverse Voltage Per Segment Not designed for reverse bias V
Operating Temperature Range
-40 °C to +85 °C °C
Storage Temperature Range
-40 °C to +85 °C °C
Electrical / Optical Characteristics @ T
A
= 25 °C
White
Parameter Symbol Min. Typ. Max. Unit Test Condition
Average Luminous Intensity I
V
24 40 – mcd I
F
= 5 mA
Chromaticity Coordinates (x,y) See Figure 1 I
F
= 5 mA
Forward Voltage, Per Segment V
F
– 2.95 3.8 V I
F
= 5 mA
Reverse Current, Per Segment
[1]
I
R
– – 100
µA
V
R
= 5 V
Luminous Intensity Matching Ratio I
V-m
– – 2:1 – I
F
= 5 mA
Note 1. Indicates production nal test condition only. Long term reverse biasing is not recommended.