Connection and Installation
Connect to the eTape by attaching a 4 pin connector with pre-soldered wires to the Crimpflex
pins. Do not solder directly to the Crimpflex pins. The inner two pins (pins 2 and 3) are the
sensor output (Rsense). The outer pins (pins 1 and 4) are the reference resistor (Rref) which can
be used for temperature compensation. Suspend the eTape sensor in the fluid to be
measured. To work properly the sensor must remain straight and must not be bent vertically or
longitudinally. For best results install the sensor inside a section of 1-inch diameter PVC pipe.
Double sided adhesive tape may be applied to the upper back portion of the sensor to
suspend the sensor in the container to be measured. However, the liquid must be allowed to
interact freely with both sides of the sensor. The vent hole located above the max line allows
the eTape to equilibrate with atmospheric pressure. The vent hole is fitted with a hydrophobic
filter membrane to prevent the eTape from being swamped if inadvertently submerged.
Sample Circuits
Custom Applications
The eTape sensor can be manufactured in custom lengths to fit any application.
Contact Milone Technologies if you have an application that requires specific
length, configuration or output characteristics.
Technical Support
If you require technical support for the eTape liquid level sensor, please contact our technical
support department by email at: techsupport@milonetech.com.
Milone Technologies, Inc - 17 Ravenswood Way - Sewell, New Jersey 08080 - Phone: (856) 270-2688
Email: info@milonetech.com Web: www.milonetech.com
Continuous Fluid Level Sensor
PN-12110215TC-12