3386H-DF6-503

https://www.phoenixcontact.com/us/products/2800716
09/10/2014Page1/4
Surge protection device-SYS N4X 120/240HLD-2800716
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Indoor/outdoor lightning arrester and TVSS system for 120/208-240 V
Product description
Combination lightning arrester and TVSS for 120/208-240 V. Components are housed in an IP66/NEMA 4X cabinet. 
Key commercial data
Packing unit 1 pc
Weight per Piece (excluding packing) 1.0 GRM
Custom tariff number 85363090
Country of origin Germany
Technical data
Dimensions
Height 500 mm
Width 400 mm
Depth 210 mm
Ambient conditions
Degree of protection IP66 / NEMA 4X
Ambient temperature (operation) -40 °C ... 80 °C
General
NEMA power supply system 120/240 V High-Leg Delta
Housing material Stainless steel
Mounting type Surface/Wall mounting
Surge protection fault message Remote indicator contact
Protective circuit
https://www.phoenixcontact.com/us/products/2800716
09/10/2014Page2/4
Surge protection device-SYS N4X 120/240HLD-2800716
Technical data
Protective circuit
IEC test classification I + II
EN type T1
Nominal voltage U
N
< 240 V
Maximum continuous operating voltage U
C
275 V AC
Impulse discharge current (10/350)µs charge 25 As
Impulse discharge current (10/350)˽µs, peak value l
imp
50 kA (per mode)
Response time ≤ 25 ns
Follow current quenching capacity If 50 kA
Connection, protective circuit
Connection method Screw connection
Conductor cross section stranded min. 16 mm²
Conductor cross section stranded max. 35 mm²
Conductor cross section solid min. 10 mm²
Conductor cross section solid max. 50 mm²
Conductor cross section AWG/kcmil min. 6
Conductor cross section AWG/kcmil max 1
Remote indicator contact
Connection method Screw connection
Conductor cross section stranded min. 0.14 mm²
Conductor cross section stranded max. 1.5 mm²
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section AWG/kcmil min. 28
Conductor cross section AWG/kcmil max 16
NEMA / UL data
UL type type 2
Nominal discharge current I
n
(without reference direction)
20 kA
Maximum Surge Current per Phase 50 kA
Short-circuit current rating (SCCR) 50 kA
Standards and Regulations
Standards/regulations
UL 1449 3
rd
edition, Sept. 2009
IEC 60643-1
EN 61643-11
CAN/CSA-C22.2 No. 8
https://www.phoenixcontact.com/us/products/2800716
09/10/2014Page3/4
Surge protection device-SYS N4X 120/240HLD-2800716
Classifications
eCl@ss
eCl@ss 4.0 27140201
eCl@ss 4.1 27140201
eCl@ss 5.0 27130801
eCl@ss 5.1 27130801
eCl@ss 6.0 27130805
eCl@ss 7.0 27130805
eCl@ss 8.0 27130805
ETIM
ETIM 3.0 EC000942
ETIM 4.0 EC000941
ETIM 5.0 EC000941
UNSPSC
UNSPSC 6.01 30212010
UNSPSC 7.0901 39121610
UNSPSC 11 39121610
UNSPSC 12.01 39121610
UNSPSC 13.2 39121620
Approvals
Approvals
Approvals
ETLus / cETL / cETLus
Ex Approvals
Approvals submitted
Approval details
ETLus

3386H-DF6-503

Mfr. #:
Manufacturer:
Bourns
Description:
Trimmer Resistors - Through Hole TRIMMER - 3/8" SQ ST CERMET
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet