MC10H130
http://onsemi.com
2
Table 1. MAXIMUM RATINGS
Symbol Characteristic Rating Unit
V
EE
Power Supply (V
CC
= 0) −8.0 to 0 Vdc
V
I
Input Voltage (V
CC
= 0) 0 to V
EE
Vdc
I
out
Output Current Continuous
Surge
50
100
mA
T
A
Operating Temperature Range 0 to +75 °C
T
stg
Storage Temperature Range Plastic
Ceramic
−55 to +150
−55 to +165
°C
°C
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
Table 2. ELECTRICAL CHARACTERISTICS (V
EE
= −5.2 V ±5%) (Note 1)
0° 25° 75°
Symbol Characteristic Min Max Min Max Min Max Unit
I
E
Power Supply Current − 38 − 35 − 38 mA
I
inH
Input Current High
Pins 6, 11
Pins 7, 9, 10
Pins 4, 5, 12, 13
−
−
−
468
545
434
−
−
−
275
320
255
−
−
−
275
320
255
mA
I
inL
Input Current Low 0.5 − 0.5 − 0.3 −
mA
V
OH
High Output Voltage −1.02 −0.84 −0.98 −0.81 −0.92 −0.735 Vdc
V
OL
Low Output Voltage −1.95 −1.63 −1.95 −1.63 −1.95 −1.60 Vdc
V
IH
High Input Voltage −1.17 −0.84 −1.13 −0.81 −1.07 −0.735 Vdc
V
IL
Low Input Voltage −1.95 −1.48 −1.95 −1.48 −1.95 −1.45 Vdc
1. Each MECL 10H series circuit has been designed to meet the dc specifications shown in the test table, after thermal equilibrium has been
established. The circuit is in a test socket or mounted on a printed circuit board and transverse air flow greater than 500 linear fpm is
maintained. Outputs are terminated through a 50 W resistor to −2.0 V.
Table 3. AC PARAMETERS
0° 25° 75°
Symbol Characteristic Min Max Min Max Min Max Unit
t
pd
Propagation Delay
Data
Set, Reset
Clock, CE
0.4
0.6
0.5
1.6
1.7
1.6
0.4
0.7
0.5
1.7
1.8
1.7
0.4
0.8
0.6
1.8
1.9
1.8
ns
t
r
Rise Time 0.5 1.6 0.5 1.7 0.5 1.8 ns
t
f
Fall Time 0.5 1.6 0.5 1.7 0.5 1.8 ns
t
set
Set−up Time 2.2 − 2.2 − 2.2 − ns
t
hold
Hold Time 0.7 − 0.7 − 0.7 − ns
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.