EV20-0.5-02-18M

DATASHEET
Common-mode Chokes EV/EH series
Common-mode Suppression Chokes
Rated currents up to 5 A
Broadband attenuation characteristics
Low magnetic leakage flux
UL rated materials
RoHS compliant
Technical specifications
Maximum continuous operating voltage
250 VAC @ 50°C
Operating frequency
DC to 400 Hz
Rated currents
0.3 to 5 A
Overcurrent
1.5x Inominal for 1 minute, once per hour
winding-to-winding @ 25°C
3000 VAC, 60 sec, guaranteed
2000 V, 50 Hz, 2 sec, factory test
Temperature range (operation and storage)
-25°C to +100°C (25/100/21)
Flammability corresponding to
UL 94 V-0
Test conditions
Measuring frequency
10 kHz; 5 mA <16 μH;
500 μA >16 μH <160 μH;
50 μA >160 μH >16 mH;
50 mV >16 mH <160 mH
Inductance tolerance ±30%
Resistance
Tolerance max. ±15% @ 25°C; ≤20 mΩ, 1 A;
>20 mΩ ≤200 mΩ, 100 mA; >200 mΩ ≤2 V, 10 mA
Electrical characteristics
@ 25°C ±2°C
Approvals
Common-mode suppression chokes are mainly used
to filter noise on AC power lines. Noise on
commercial power lines could enter the equipment
and disturb the proper function. Noise generated by
the equipment for example from switch mode power
supplies need to be filtered and the spread of such
generated noise need to be suppressed. Common-
mode suppression chokes together with line bypass
capacitors building an AC EMI suppression filter
device.
Features and benefits
Rated currents up to 5 A
Compact and light weight
Low magnetic leakage flux
Sectional winding
Standard foot print
Broad range of available inductances and current
ratings
Custom-specific versions
Schaffner offers you also EMI measure- ment service
to verify that your design will pass the required
safety standards
Typical applications
Input filters for switch mode power supplies
Filters to reduce leaking noise
TVs, VCRs, multimedia and audio equipment
Office automation, communications and other
electronic devices
Electric ballast
AC/AC converters
Typical electrical schematic
2 EMC/EMI Products Schaffner Group Datasheets 2017
Choke selection table
EV choke EH choke L nominal DC resistance Rated current Weight
(±30%) R I (50°C)
[mH] [mΩ] [A] [g]
EV 20-0.3-02-33M EH 20-0.3-02-33M 33 1780 0.3 10
EV 20-0.5-02-18M EH 20-0.5-02-18M 18 725 0.5 10
EV 20-0.8-02-5M6 EH 20-0.8-02-5M6 5.6 245 0.8 10
EV 20-1.0-02-3M9 EH 20-1.0-02-3M9 3.9 168 1.0 10
EV 20-1.2-02-3M3 EH 20-1.2-02-3M3 3.3 127 1.2 10
EV 20-1.5-02-1M8 EH 20-1.5-02-1M8 1.8 72 1.5 10
EV 20-2.0-02-0M8 EH 20-2.0-02-0M8 0.82 38 2.0 10
EV 24-0.5-02-44M EH 24-0.5-02-44M 44 1250 0.5 18
EV 24-0.8-02-18M EH 24-0.8-02-18M 18 438 0.8 18
EV 24-1.0-02-10M EH 24-1.0-02-10M 10 244 1.0 18
EV 24-1.5-02-4M5 EH 24-1.5-02-4M5 4.5 116 1.5 18
EV 24-2.0-02-2M5 EH 24-2.0-02-2M5 2.5 62 2.0 18
EV 24-3.0-02-1M2 EH 24-3.0-02-1M2 1.2 29 3.0 18
EV 24-4.0-02-0M5 EH 24-4.0-02-0M5 0.5 16 4.0 18
EV 28-1.0-02-36M EH 28-1.0-02-36M 36 591 1.0 31
EV 28-1.5-02-20M EH 28-1.5-02-20M 20 282 1.5 31
EV 28-2.0-02-11M EH 28-2.0-02-11M 11 162 2.0 31
EV 28-3.0-02-5M0 EH 28-3.0-02-5M0 5 79 3.0 31
EV 28-4.0-02-2M3 EH 28-4.0-02-2M3 2.3 40 4.0 31
EV 28-5.0-02-1M1 EH 28-5.0-02-1M1 1.1 27 5.0 31
EV 35-1.0-02-90M EH 35-1.0-02-90M 90 628 1.0 70
EV 35-2.0-02-20M EH 35-2.0-02-20M 20 150 2.0 70
EV 35-3.0-02-10M EH 35-3.0-02-10M 10 72 3.0 70
EV 35-4.0-02-5M0 EH 35-4.0-02-5M0 5 53 4.0 70
EV 35-5.0-02-3M6 EH 35-5.0-02-3M6 3.6 33 5.0 70
All wires rated 130°C or higher.
Typical choke attenuation
Per CISPR 17; 50 Ω/50 Ω asym
EV/EH 20 types
EV/EH 24 types
EV/EH 28 types
EV/EH 35 types
A = 33 mH
B = 18 mH
C = 5.6 mH
D = 3.9 mH
E = 3.3 mH
F = 1.8 mH
G = 0.8 mH
A = 44 mH
B = 18 mH
C = 10 mH
D = 5.5 mH
E = 2.5 mH
F = 1.2 mH
G = 0.5 mH
A = 36 mH
B = 20 mH
C = 11 mH
D = 5 mH
E = 2.3 mH
F = 1.1 mH
A = 90 mH
B = 20 mH
C = 10 mH
D = 5 mH
E = 3.6 mH
3 EMC/EMI Products Schaffner Group Datasheets 2017
Mechanical data
EV 20 EV 35
EV 24 and 28 EH 20 to 35

EV20-0.5-02-18M

Mfr. #:
Manufacturer:
Description:
Common Mode Filters / Chokes 18mH 0.5A - VERTICAL COMMN-MODE SPPRESSN
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union