16
FN8132.2
October 16, 2015
V
TRIP
Programming Specifications V
CC
= 1.7-5.5V; Temperature = 0°C to 70°C
Parameter Description Min. Max. Unit
t
VPS
SCK V
TRIP
Program Voltage Setup time 1 µs
t
VPH
SCK V
TRIP
Program Voltage Hold time 1 µs
t
P
V
TRIP
Program Pulse Width 1 µs
t
TSU
V
TRIP
Level Setup time 10 µs
t
THD
V
TRIP
Level Hold (stable) time 10 ms
t
WC
V
TRIP
Write Cycle Time 10 ms
t
RP
V
TRIP
Program Cycle Recovery Period (Between successive programming cycles) 10 ms
t
VPO
SCK V
TRIP
Program Voltage Off time before next cycle 0 ms
V
P
Programming Voltage 15 18 V
V
TRAN
V
TRIP
Programed Voltage Range 1.7 5.0 V
V
ta1
Initial V
TRIP
Program Voltage accuracy (V
CC
applied-V
TRIP
) (Programmed at 25°C.) -0.1 +0.4 V
V
ta2
Subsequent V
TRIP
Program Voltage accuracy [(V
CC
applied-V
ta1
)-V
TRIP
]
(Programmed at 25°C.)
-25 +25 mV
V
tr
V
TRIP
Program Voltage repeatability (Successive program operations.) (programmed at
25°C)
-25 +25 mV
V
tv
V
TRIP
Program variation after programming (0-75°C). (programmed at 25°C) -25 +25 mV
V
TRIP
programming parameters are periodically sampled and are not 100% tested.
X5328, X5329