TCP−5047UB
www.onsemi.com
3
TYPICAL SPECIFICATIONS
Representative Performance Data at 255C
Table 2. PERFORMANCE DATA
Parameter Min Typ Max Unit
Operating Bias Voltage 1.0 24 V
Capacitance (V
bias
= 2 V) 4.277 4.70 5.123 pF
Capacitance (V
bias
= 24 V) 0.920 1.011 1.102 pF
Tuning Range (1 V − 24 V) 4.80 5.25 5.60
Tuning Range (2 V − 24 V) 4.20 4.65 5.30
Leakage Current (V
bias
= 24 V) 0.1
mA
Operating Frequency 700 2700 MHz
Quality Factor @ 700 MHz, 2 V (Note 5) 70
Quality Factor @ 700 MHz, 24 V (Note 5) 80
Quality Factor @ 2.4 GHz, 2 V (Note 5) 45
Quality Factor @ 2.4 GHz, 24 V (Note 5) 40
IP3 (V
bias
= 2 V) (Notes 1, 3 and 5) 70 dBm
IP3 (V
bias
= 24 V) (Notes 1, 3 and 5) 85 dBm
2nd Harmonic (V
bias
= 2 V) (Notes 2, 3 and 5) −65 dBm
2nd Harmonic (V
bias
= 24 V) (Notes 2, 3 and 5) −80 dBm
3rd Harmonic (V
bias
= 2 V) (Notes 2, 3 and 5) −45 dBm
3rd Harmonic (V
bias
= 24 V) (Notes 2, 3 and 5) −75 dBm
Average Transition Time (Cmin ³ Cmax) (Notes 4
and 5)
66
ms
Average Transition Time (Cmax ³ Cmin) (Notes 4
and 5)
48
ms
1. f
1
= 850 MHz, f
2
= 860 MHz, Pin 25 dBm/Tone
2. 850 MHz, Pin +34 dBm
3. IP3 and Harmonics are measured in the shunt configuration in a 50 W environment
4. RF
IN
and RF
OUT
are both connected to DC ground
5. Sample testing only. Average Transition Time for all start and stop voltage combinations between 2 V and 24 V is 50 ms.