https://www.phoenixcontact.com/us/products/2904912
05/18/2015Page4/6
Temperature measuring transducer-MACX PL-EX-T-UIREL-UP-
SP-2904912
Technical data
General
[Ex ia Da] IIIC
Ex nA nC ic IIC T4 Gc X
UL, USA / Canada UL 508 Listed
Functional Safety (SIL) SIL 2
Safety data
Max. internal inductance L
i
negligible
Max. internal capacitance C
i
44 nF
Max. output voltage U
o
6 V
Max. output current I
o
7.4 mA
Max. output power P
o
11 mW
Group IIC
Max. external inductivity L
o
100 mH
Max. external capacity C
o
1.3 µF
Group IIC
Max. external inductivity L
o
10 mH
Max. external capacity C
o
1.7 µF
Group IIC
Max. external inductivity L
o
1 mH
Max. external capacity C
o
2.6 µF
Group IIC
Max. external inductivity L
o
0 mH
Max. external capacity C
o
10 µF
Group IIB
Max. external inductivity L
o
100 mH
Max. external capacity C
o
6.8 µF
Group IIB
Max. external inductivity L
o
10 mH
Max. external capacity C
o
9.2 µF
Safety-related maximum voltage U
m
253 V AC/DC
EMC data
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 2 %
Designation Fast transients (burst)