LPV-100-5

SPECIFICATION
MODEL LPV-100-5 LPV-100-12 LPV-100-15 LPV-100-24 LPV-100-36 LPV-100-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V 12V 15V 24V 36V 48V
12A 8.5A 6.7A 4.2A 2.8A 2.1A
0 ~ 12A 0 ~ 8.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 2.8A 0 ~ 2.1A
60W 102W 100.5W 100.8W 100.8W 100.8W
80mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p
±8.0%
±1.0%
±6.0%
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
80% 85%
±2.0%
±5.0%
87% 88% 88% 89%
5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 41.4 ~ 48.6V 55.2 ~ 64.8V
2.2A/115VAC 1.2A/230VAC
COLD START 75A(twidth=700 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A( 80% load), EN61000-3-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A, EAC TP TC 020
-25 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
703Khrs min. MIL-HDBK-217F (25 )
190*52*37mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure.
0.63Kg;20pcs/13.6Kg/0.55CUFT
Protection type : Shut down o/p voltage, re-power on to recover
100W Single Output Switching Power Supply
Features :
LPV-100 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
File Name:LPV-100-SPEC 2018-01-10
Constant voltage design
Universal AC input / Full range
Fully encapsulated with IP67 level (Note.8)
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)(Note 7.)
2 years warranty
50ms/230VAC 14ms/115VAC at full load
2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC
±℃ 0.03%/ (0 ~ 50 )
EMC IMMUNITY
EMC EMISSION
IP67
UL8750,CSA C22.2 No 250.13-12 UL879,CSA C22.2 No.207-M89,BIS IS15885(for LPV-100-12,LPV-100-24 only),,
EAC TP TC 004,IP67 approved. Design refer to EN60950-1
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUEL
THOMAS SAMUEL
(for 12V,24V only)
Mechanical Specification
File Name:LPV-100-SPEC 2018-01-10
fosc : 65KHz
PWM
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
CONTROL
&
Block Diagram
DETECTION
CIRCUIT
O.V.P.
LOAD (%)
20
40
60
80
100
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD (%)
Derating Curve
LOAD (%)
Derating Curve Static Characteristics
AMBIENT TEMPERATURE ( )
LOAD (%)
175
LOAD (%)
100W Single Output Switching Power Supply
LPV-100 series
(HORIZONTAL)
-15 0 15 30
04050-25 60 70
Case No. LPC-100A Unit:mm
5V,12V
Others
Recommend Mounting Direction
Tcase
17
96
+V(Red)
-V(Black)
UL 1015 14AWG
UL 1015 18AWG
190
52
3.5
3.5
3.5
3.5
300±10
300±10
37
2.5
AC/N(Blue)
AC/L(Brown)
24.5
T case: Max. Case Temperature.

LPV-100-5