45MHz to 650MHz, Integrated IF
VCOs with Differential Output
MAX2605
REQUIRED INDUCTANCE vs. DESIRED VCO FIXED FREQUENCY
1900
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
REQUIRED INDUCTANCE (nH)
45
47
49 51 53 55
57
59 61 63 65 67
69
EFFECTIVE INDUCTANCE
FROM IND TO GND
INDUCTOR VALUE
MOUNTED ON EV KIT
MEASUREMENT CONDITIONS
V
CC
= 2.75V, T
A
= 25°C,
R
LOAD
= 100||50 (100 RESISTIVE PULL-UP PARALLELED WITH 50
VNA IMPEDANCE), UNUSED OUTPUT TERMINATED IN 50,
PCB PARASITIC SHUNT CAPACITANCE (IND TO GND) = 0.45pF
THE INDUCTANCE LISTED IS THE PRECISE NOMINAL INDUCTANCE VALUE
REQUIRED FROM IND TO GND IN ORDER TO GUARANTEE THE VCO
CAN TUNE TO THE DESIRED FIXED FREQUENCY, OVER ALL OPERATING
CONDITIONS AND WORST-CASE COMPONENT
VALUES (±2% INDUCTOR AND IC PROCESS VARIATION).
DESIRED VCO FIXED FREQUENCY (MHz)
Figure 1. MAX2605 Required Inductance vs. Desired VCO Fixed Frequency
MAX2605–MAX2609
Maxim Integrated
7
45MHz to 650MHz, Integrated IF
VCOs with Differential Output
MAX2606
REQUIRED INDUCTANCE vs. DESIRED VCO FIXED FREQUENCY
790
740
690
640
590
540
490
440
390
340
290
240
190
REQUIRED INDUCTANCE (nH)
75
80
85 90 95 100
105
110
115 120 125 130
135
EFFECTIVE INDUCTANCE
FROM IND TO GND
INDUCTOR VALUE
MOUNTED ON EV KIT
140
70 140
145 150
MEASUREMENT CONDITIONS
V
CC
= 2.75V, T
A
= 25°C,
R
LOAD
= 100||50 (100 RESISTIVE PULL-UP PARALLELED WITH 50
VNA IMPEDANCE), UNUSED OUTPUT TERMINATED IN 50,
PCB PARASITIC SHUNT CAPACITANCE (IND TO GND) = 0.45pF
THE INDUCTANCE LISTED IS THE PRECISE NOMINAL INDUCTANCE VALUE
REQUIRED FROM IND TO GND IN ORDER TO GUARANTEE THE VCO
CAN TUNE TO THE DESIRED FIXED FREQUENCY, OVER ALL OPERATING
CONDITIONS AND WORST-CASE COMPONENT
VALUES (±2% INDUCTOR AND IC PROCESS VARIATION).
DESIRED VCO FIXED FREQUENCY (MHz)
Figure 2. MAX2606 Required Inductance vs. Desired VCO Fixed Frequency
MAX2605–MAX2609
Maxim Integrated
45MHz to 650MHz, Integrated IF
VCOs with Differential Output
MAX2607
REQUIRED INDUCTANCE vs. DESIRED VCO FIXED FREQUENCY
160
150
140
130
120
110
100
90
80
70
60
50
40
REQUIRED INDUCTANCE (nH)
160
170
180 190 200 210 220
230
240 250 260 270 280
INDUCTOR VALUE
MOUNTED ON EV KIT
30
150
290
300
170
EFFECTIVE INDUCTANCE
FROM IND TO GND
MEASUREMENT CONDITIONS
V
CC
= 2.75V, T
A
= 25°C,
R
LOAD
= 100||50 (100 RESISTIVE PULL-UP PARALLELED WITH 50
VNA IMPEDANCE), UNUSED OUTPUT TERMINATED IN 50,
PCB PARASITIC SHUNT CAPACITANCE (IND TO GND) = 0.45pF
THE INDUCTANCE LISTED IS THE PRECISE NOMINAL INDUCTANCE VALUE
REQUIRED FROM IND TO GND IN ORDER TO GUARANTEE THE VCO
CAN TUNE TO THE DESIRED FIXED FREQUENCY, OVER ALL OPERATING
CONDITIONS AND WORST-CASE COMPONENT
VALUES (±2% INDUCTOR AND IC PROCESS VARIATION).
DESIRED VCO FIXED FREQUENCY (MHz)
Figure 3. MAX2607 Required Inductance vs. Desired VCO Fixed Frequency
MAX2605–MAX2609
Maxim Integrated
9

MAX2608EUT+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
VCO Oscillators 300 MHz to 500 MHz IF VCOs w/Diff Out
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union