Document Number: 38-07146 Rev. *H Page 4 of 15
Maximum Ratings
Supply Voltage to Ground Potential................–0.5V to +7.0V
DC Input Voltage (Except Ref) ..............–0.5V to V
DD
+ 0.5V
DC Input Voltage REF ...........................................–0.5 to 7V
Storage Temperature.................................. –65°C to +150°C
Junction Temperature.................................................. 150°C
Static Discharge Voltage
(MIL-STD-883, Method 3015)....................................>2000V
Operating Conditions for Commercial Temperature Devices
Parameter Description Min Max Unit
V
DD
Supply Voltage 3.0 3.6 V
T
A
Operating Temperature (Ambient Temperature) 0 70 °C
C
L
Load Capacitance, below 100 MHz – 30 pF
Load Capacitance, from 100 MHz to 133 MHz – 15 pF
C
IN
Input Capacitance
[6]
–7pF
t
PU
Power up time for all V
DD
s to reach minimum specified voltage
(power ramps must be monotonic)
0.05 50 ms
Electrical Characteristics for Commercial Temperature Devices
Parameter Description Test Conditions Min Max Unit
V
IL
Input LOW Voltage – 0.8 V
V
IH
Input HIGH Voltage 2.0 – V
I
IL
Input LOW Current V
IN
= 0V – 50.0 μA
I
IH
Input HIGH Current V
IN
= V
DD
–100.0μA
V
OL
Output LOW Voltage
[7]
I
OL
= 8 mA (–1, –2, –3, –4)
I
OL
= 12 mA (–1H, –5H)
–0.4V
V
OH
Output HIGH Voltage
[7]
I
OH
= –8 mA (–1, –2, –3, –4)
I
OH
= –12 mA (–1H, –5H)
2.4 – V
I
DD
(PD mode) Power Down Supply Current REF = 0 MHz – 12.0 μA
I
DD
Supply Current Unloaded outputs, 100 MHz REF,
Select inputs at V
DD
or GND
– 45.0 mA
– 70.0
(–1H,–5H)
mA
Unloaded outputs, 66 MHz REF
(–1, –2, –3, –4)
– 32.0 mA
Unloaded outputs, 33 MHz REF
(–1, –2, –3, –4)
– 18.0 mA
Switching Characteristics for Commercial Temperature Devices
Parameter
[8]
Name Test Conditions Min Typ. Max Unit
t
1
Output Frequency 30 pF load, All devices 10 – 100 MHz
t
1
Output Frequency
20 pF load, –1H, –5H devices
[9]
10 – 133.3 MHz
t
1
Output Frequency 15 pF load, –1, –2, –3, –4 devices 10 – 133.3 MHz
t
PD
Duty Cycle
[7, 8]
= t
2
÷ t
1
(–1, –2, –3, –4, –1H, –5H)
Measured at 1.4V, F
OUT
= 66.66 MHz
30 pF load
40.0 50.0 60.0 %
t
PD
Duty Cycle
[7, 8]
= t
2
÷ t
1
(–1, –2, –3, –4, –1H, –5H)
Measured at 1.4V, F
OUT
< 50 MHz
15 pF load
45.0 50.0 55.0 %
Notes
6. Applies to both Ref Clock and FBK.
7. Parameter is guaranteed by design and characterization. Not 100% tested in production.
8. All parameters are specified with loaded outputs.
9. CY2308–5H has maximum input frequency of 133.33 MHz and maximum output of 66.67 MHz.