INPUT
parameter conditions/description min typ max units
voltage
85
120
264
370
Vac
Vdc
frequency 47 63 Hz
current 0.5 A
inrush current at240Vac,25°C,coldstart 70 A
leakagecurrent 0.25 mA
no load power consumption 0.10 W
OUTPUT
parameter conditions/description min typ max units
capacitiveload
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
3,500
2,100
1,600
1,300
850
420
μF
μF
μF
μF
μF
μF
initialsetpointaccuracy atfullload,25°C ±2 %
lineregulation highlinetolowlineatfullload ±0.5 %
loadregulation 10%~100%load ±1 %
hold-up time at 115 Vac 12 ms
switchingfrequency 65 kHz
temperaturecoefcient ±0.05 %/°C
PROTECTIONS
parameter conditions/description min typ max units
overvoltageprotection hiccup,autorecovery
overcurrentprotection 110 %
short circuit protection hiccup,autorecovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolationvoltage input to output 4,000 Vac
safetyapprovals IEC62368-1/60950-1,EN62368-1/60950-1,UL62368-1/60950-1
safetyclass class II
EMI/EMC
EN55032ClassB,FCCPart15ClassB,EN61000-
6-3, EN 61000-3-2, EN 61000-3-3, EN 55024,
EN 61204-3, EN 61000-6-1
MTBF asperMIL-STD-217F,at115Vac,25°C,GB 300,000 hours
life time at40°C,75%load 3 years
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operatingtemperature seederatingcurve -25 70 °C
storagetemperature -40 85 °C
operatinghumidity non-condensing 93 %
operatingaltitude 3000 m