LDA150W-12

lLDA15F
lLDA30F
lLDA50F
lLDA75F
LDA-24
4 Assembling and
Installation Method
4.1 Installation method
n
n
When two or more power supplies are used side by side, position
them with proper intervals to allow enough air ventilation. Ambient
temperature around each power supply should not exceed the
temperature range shown in derating curve.
In case of metal chassis, keep the distance between l & l for to
insulate between lead of component and metal chassis. If it is
less than l & l , insert the insulation sheet between power supply
and metal chassis.
12
12
4.2 Derating
nThe operative ambient temperature is different by with/without
case cover or mounting position. Please refer drawings as below.
lLDA10F
=2 4mm min
2
2
2
CN1
2
=1 8mm min
CN1
2
Note:
In the hatched area, the specification of Ripple, Ripple Noise is dif-
ferent from other area.
LDA
Instruction Manual
AC-DC Power Supplies Open Frame/Enclosed type
lLDA100W
lLDA150W
lLDA300W
lLDA300W
Mounting method
LDA-25
Note:
In the slanted area, the specification of Ripple, Ripple Noise is dif-
ferent from other area.
Note:
Ventilation is required so that part A of heat sink is below 85 in
any case. Please flow air to the components to the direction of Air
or Air .
n
n
n
(F) mounting is not possible when unit is with case cover, but if
need to operate unit by (F) positioning with case cover, tempera-
ture / load derating is necessary. For more details, please consult
our sales or engineering departments.
The mounting screw should be M3. The hatched area shows the
allowance of metal parts for mounting.
Please be carefull with that metal parts do not touch mounted
parts at front side, where major components are mounted, when
a power supply is installed with them.
4.3 Mounting screw
lLDA10F
nWhen unit mounted except below drawings, it is required to con-
sider ventilated environment by forced air cooling for tempera-
ture/load derating. For details, please consult our sales or engi-
neering departments.
0
20
40
80
60
100
0-10 10 20 30 40 50 60 70
(B), (C), (D), (E), (F) mounting
Ambient temperature [ ]
Load factor [%]
Convection
Forced air
(A) mounting
The rated power is different depend on Forced Air/Convection
cooling (Please refer Chart in right hand side).
Convection
Forced air
120W
200W
207W
204W
210W
216W
216W
210W
201.6W
-3
-5
-9
-12
-15
-18
-24
-30
-48
180W
300W
306W
324W
330W
306W
336W
300W
302.4W
Output
voltage
TB1
TB2
Air
Air
Part A
CN1
CN1
CN1
CN1
(A)
(B) (C) (D)
CN1
CN1
(E)
(F)
Normal position
LDA
Instruction Manual
AC-DC Power Supplies Open Frame/Enclosed type
LDA-26
Unit[mm]
nKeep isolation distance between screw and internal components
in case of option ”-S”, ”-SN”, as below chart.
lLDA75F - LDA150W
lLDA30F - LDA75F
lLDA100W - LDA300W
lLDA300W
TB1
TB2
10
10
10
10
10
10
10
10
26
10
10
165
9
99
9
9
99
9
CN1
5 Ground
6 Others
nWhen installing the power supply with your unit, ensure that the in-
put FG terminal or mounting hole FG is connected to safety
ground of the unit. However when applying the safety agency,
connect the input FG terminal to safety ground of the unit.
n
n
n
This power supply is the rugged PCB type. Do not drop conduc-
tive objects in the power supply.
At light load, there remains high voltage inside the power supply
for a few minutes after power OFF. So, at maintenance, take care
about electric shock.
This power supply is manufactured by SMD technology. The
stress to PCB like twisting or bending causes the defect of the
unit, so handle the unit with care.
LDA
lLDA15F - LDA50F lLDA10F LDA15F
Instruction Manual
AC-DC Power Supplies Open Frame/Enclosed type

LDA150W-12