B88069X2920C103

Surge arrester
2-electrode arrester
Series/Type: A80-A250X
Ordering code: B88069X2920C103
Version/Date: Issue 03 / 2010-11-02
Version: 6
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar)
Surge arrester
Identification/Classification 2:
(header 2 + bottom left header bar)
2-electrode arrester
Ordering code:
(top right header bar)
B88069X2920C103
Series/Type:
(top right header bar)
A80-A250X
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X2920C103
2-electrode arrester A80-A250X
PPD AB PD / PPD AB PM Issue 03 / 2010-11-02
Please read Cautions and warnings and Page 2 of 4
Important notes at the end of this document.
Features Applications
Standard size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Modem
XDSL-splitter
Tuner
Data lines
Antenna
Electrical specifications
DC spark-over voltage
1) 2)
250
± 20
V
%
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 550
< 500
< 700
< 650
V
V
V
V
Service life
10 operations 50 Hz, 1 s 20 A
1 operation 50 Hz, 0.18 s (9 cycles) 100 A
10 operations 8/20 µs 20 kA
1 operation 8/20 µs
25 kA
2 operations 10/350 µs
2.5 kA
300 operations 10/1000 µs 100 A
Insulation resistance at 100 V
DC
> 10
GΩ
Capacitance at 1 MHz < 1.5 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
~ 0.5
~ 60
V
A
V
Weight ~ 1.5 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, blue negative
250 YY O
250 - Nominal voltage
YY - Year of production
O - Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms and current waveforms in accordance with: ITU-T Rec. K.12 ; IEC 61643-21 and DIN 57845/VDE0845
Surge arrester B88069X2920C103
2-electrode arrester A80-A250X
PPD AB PD / PPD AB PM Issue 03 / 2010-11-02
Please read Cautions and warnings and Page 3 of 4
Important notes at the end of this document.
Dimensional drawing in mm
Cautions and warnings
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.

B88069X2920C103

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors A80-A250X
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet