No. MATERIALS NAME
MATERIAL REMARK
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0538-A
PAGENAME OF DRAWING DRAWING No.
Product Drawing CTR-3730-A
TSB-08-01-05(00) form-6(A4)
QU
<The specifications may be changed without any notice.>
6
[4] Test circuit
F1
CN1-1,2
Vin
CN1-3,4
GND
CN1-6
Vst
Q6
T1
6
9
1
2
3
4
5
V
1000:1
F
2
CN1-5
Vbr
CN1-7
Vrmt
CL1
CN2-1
Vhigh1
RL1
CN3-1
Vlow1
A
Iout1
CL2
CN2-2
Vhigh2
RL2
CN3-2
Vlow2
A
Iout2
CL3
CN4-1
Vhigh3
RL3
CN5-1
Vlow3
A
Iout3
CL4
CN4-2
Vhigh4
RL4
CN5-2
Vlow4
A
Iout4
T2
6
9
1
3
4
5
Note.4-1.SW1(ON/OFF) Operation is as following;
RL1∼4:Load resistance(7W or more)
CL1∼4:Distribution capacity capacitor(3kV or more)
※1.When any of the load is opened, the alarm output becomes 5V.
※2.If the inverter detects open output connector for about 3 seconds it will shut down.
Input current 3 is an input current after operation stops.
Shutdown
Function
※2
No shutdown
(Operation)
Shutdown
Shutdown
Note4-3.Safety Function
Shutdown
Shutdown
A
V
Vin
10.8
∼
13.2V
Iin
V
Vst
Vbr
0∼1.9V
a
b
SW2
Rbr
0
∼
20kΩ
V
V
a
b
SW1
Vrmt
5V
CP
3
F2
SW1
a
b
Operation
Non operation
Non operationOpen
Operation of unit
Note.4-2.SW2(ON/OFF) Operation is as following;
SW2
a
b
*Variable resistance dimming
VR=0~20k
*Voltage dimming
Vbr=0~1.9V
Operation of unit
Alarm Signal Function
(CN1-6)
※1
0.5V max.
4.5∼5.5V
4.5∼5.5V
4.5
∼
5.5V
4.5∼5.5V
Conditions
Normality
Load (Lamp)
one open
Load (Lamp)
Two open
Load (Lamp)
Three open
Load (Lamp)
Four open
V
Note4-4.Safety Function
1000:1
A
~
V
~
F
A
Digital Multiple Meter(ADVA NTEST R6451A or
equivalent)
DC Current Meter(ADVANTEST R6451A or
equivalent)
True RMS Meter(KEITHLEY 2001 or
equivalent.)
High Frequency Current Meter(KEITHLEY 2001 or
equivalent)
High Voltage Probe (Tektronix P3000 or equivalent)
Frequency Countor(ADVANTE ST R6452A or
equivalent)