9
Electrical Speci cations (DC)
Over recommended operating T
A
= -40°C to 85°C, I
F
= 5mA to 10mA, unless otherwise speci ed.
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Output Withstand
Voltage
|V
O(OFF)
|6065 V
V
F
=0.8V, I
O
=250 A, T
A
=25C
55 V
V
F
=0.8V, I
O
=250 A
5
Output Leakage
Current
I
O(OFF)
0.5 100 nA
V
F
=0.8V, V
O
=60V, T
A
=25C
1
A
V
F
=0.8V, V
O
=60V 6
Output O set
Voltage
|V
(OS)
|1
V
I
F
=5mA, I
O
=0mA
Input Reverse
Breakdown Volt-
age
V
R
5V
I
R
=10 A
Input Forward
Voltage
V
F
1.1 1.3 1.65 V I
F
=5mA 8, 9
Output
On-resistance
R
(ON)
0.35 0.5
I
F
=5mA, I
O
=1A,
Pulse
30ms, T
A
=25C
10, 11 6
ASSR-1511
Connection B
R
(ON)
0.12 0.2
I
F
=5mA, I
O
=2A,
Pulse
30ms, T
A
=25C
Switching Speci cations (AC)
Over recommended operating T
A
= -40°C to 85°C, I
F
= 5mA to 10mA, unless otherwise speci ed.
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Turn On Time T
ON
0.5 1.0 ms
I
F
=5mA, I
O
=1A, T
A
=25C
12, 16
2.0 ms I
F
=5mA, I
O
=1A 13
0.25 0.5 ms
I
F
=10mA, I
O
=1A, T
A
=25C
1.0 ms I
F
=10mA, I
O
=1A
Turn O Time T
OFF
0.03 0.2 ms
I
F
=5mA, I
O
=1A, T
A
=25C
14, 16
0.5 ms I
F
=5mA, I
O
=1A 15
0.02 0.15 ms
I
F
=10mA, I
O
=1A, T
A
=25C
0.2 ms I
F
=10mA, I
O
=1A
Output Transient
Rejection
dV
O
/dt 1 7
kV/s V
O
=60V, T
A
=25C
17
Input-Output
Transient Rejection
dV
I-O
/dt 1
10 kV/s V
I-O
=1000V, T
A
=25C
18
Notes:
1. For derating, refer to Figure 1, 2, 3 and 4.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should
be added in some applications to protect against over-voltage transients.
3. Threshold to switch device is I
F
0.5mA, however, for quali ed device performance over temperature range, it is recommended to operate at
I
F
=5mA.
4. Device is considered as a two terminal device:
ASSR-1510 - pin 1, 2 shorted and pin 3, 4 shorted.
ASSR-1511 - pin 1, 2, 3 shorted and pin 4, 5, 6 shorted.
ASSR-1520 and ASSR-1530 - pin 1, 2, 3, 4 shorted and pin 5, 6, 7, 8 shorted.
5. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety speci cation, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
6. During the pulsed R
(ON)
measurement ( I
O
duration 30ms), ambient (T
A
) and case temperature (T
C
) are equal.