Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2: The RS3 series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
Input Voltage Range 2:1 and 3:1
Output Accuracy Nominal Vin and full load ±2% typ.
Line Voltage Regulation LL to HL, full load ±0.5% max.
Load Voltage Regulation 20% to 100% full load ±0.5% typ.
Minimum Load 10%
(2)
Output Ripple and Noise 20MHz limited 50mVp-p max.
Switching Frequency 20% to 100% full load 200kHz typ.
Efficiency at Full Load see Selection Guide
Quiescent Current RS3-05xxS_D 35mA typ.
Nominal input Voltage RS3-12xxS_D 25mA typ.
(Standard, /H2 and /H3) RS3-24xxS_D, SZ_DZ 20mA typ.
RS3-48xxS_D, SZ_DZ 10mA typ.
Isolation Voltage Standard (tested for 1 second) 1000VDC
(rated for 1 minute*) 500VAC / 60Hz
/H2 Version (tested for 1 second) 2000VDC
(rated for 1 minute*) 1000VAC / 60Hz
/H3 Version (tested for 1 second) 3000VDC
(rated for 1 minute*) 1500VAC / 60Hz
Isolation Capacitance (2:1 and 3:1) H1 200pF max.
(tested at 100kHz) H2/H3 30pF max.
Isolation Resistance 1GΩ min.
Short Circuit Protection (see note) Continuous
Operating Temperature Range –40°C to +71°C
Storage Temperature Range –55°C to +125°C
Relative Humidity 95% RH
Package Weight 4.7g
Packing Quantity 22 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 3303 x10³ hours
(+71°C) using MIL-HDBK 217F 745 x10³ hours
Certifications
EN General Safety Report: SPCLVD1605077-10 EN60950-1, AM2:2013
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL General Safety Report: E224736-A34 UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
Note: To protect the converter under all fault conditions, an input fuse is required. Quick-blow fuses
should be rated at 2x-3x the normal input current, time-delay fuses at 1.5x the normal input current.
Electrical Specifications (measured at T
A
= 25°C, at nominal input voltage and rated output current unless otherwise specified)
RS3-S_D/(Z)
Series
ECONOLINE
DC/DC-Converter
}
Detailed Information see
Application Notes chapter "MTBF"
RS3