www.onsemi.com
3
Table 3. LVPECL DC CHARACTERISTICS (V
CC
= 3.3 V; V
EE
= 0.0 V (Note 1))
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
I
EE
Power Supply Current 30 38 30 38 32 40 mA
V
OH
Output HIGH Voltage (Note 2) 2215 2295 2420 2275 2345 2420 2275 2345 2420 mV
V
OL
Output LOW Voltage (Note 2) 1470 1605 1745 1490 1595 1680 1490 1595 1680 mV
V
IH
Input HIGH Voltage (Single-Ended) 2135 2420 2135 2420 2135 2420 mV
V
IL
Input LOW Voltage (Single-Ended) 1490 1825 1490 1825 1490 1825 mV
V
IHCMR
Input HIGH Voltage Common Mode
Range (Differential) (Note 3)
V
PP
< 500 mV
V
PP
≥ 500 mV
1.3
1.5
2.9
2.9
1.2
1.4
2.9
2.9
1.2
1.4
2.9
2.9
V
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current
CLKn
CLKn
0.5
−300
0.5
−300
0.5
−300
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary ±0.3 V.
2. Outputs are terminated through a 50 W resistor to V
CC
− 2.0 V.
3. V
IHCMR
min varies 1:1 with V
EE
, max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential input signal.
Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies between V
PP
min and 1 V.
Table 4. LVNECL DC CHARACTERISTICS (V
CC
= 0.0 V; V
EE
= −3.3 V (Note 1))
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
I
EE
Power Supply Current 30 38 30 38 32 40 mA
V
OH
Output HIGH Voltage (Note 2) −1085 −1005 −880 −1025 −955 −880 −1025 −955 −880 mV
V
OL
Output LOW Voltage (Note 2) −1830 −1695 −1555 −1810 −1705 −1620 −1810 −1705 −1620 mV
V
IH
Input HIGH Voltage (Single-Ended) −1165 −880 −1165 −880 −1165 −880 mV
V
IL
Input LOW Voltage (Single-Ended) −1810 −1475 −1810 −1475 −1810 −1475 mV
V
IHCMR
Input HIGH Voltage Common Mode
Range (Differential) (Note 3)
V
PP
< 500 mV
V
PP
≥ 500 mV
−2.0
−1.8
−0.4
−0.4
−2.1
−1.9
−0.4
−0.4
−2.1
−1.9
−0.4
−0.4
V
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current
CLKn
CLKn
0.5
−300
0.5
−300
0.5
−300
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary ±0.3 V.
2. Outputs are terminated through a 50 W resistor to V
CC
− 2.0 V.
3. V
IHCMR
min varies 1:1 with V
EE
, max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential input signal.
Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies between V
PP