3MV1

54
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Multi-purpose Medical Filter for Power Line Noise Protection
MV Series
MV Series
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz: .07 mA
@250 VAC 50 Hz: .13 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 to 20A
Operating Ambient Temperature Range
(at rated current I
r
): -10°C to +40°C
In an ambient temperature (T
a
) higher than +40°C
the maximum operating current (I
o
) is calculated as
fo
llows: I
o
= I
r
(85-Ta)/45
• Multi-purpose medical filter
• Improved Line to Ground performance
• A good solution to emission or immunity problems
• Meets leakage current requirements of UL2601 for
health care equipment
Ordering Information
6 MV 1
Input / Output Style
1 – .250 [6.3] spade terminals
M
V Series
Current Rating
3, 6, 10 or 20A
Specifications
UL Recognized
CSA Certified
VDE Approved
Available Part Numbers
3MV1 6MV1
10MV1 20MV1
Electrical Schematic
LINE LOAD
55
RFI Power Line Filters
1
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Multi-purpose Medical Filter for Power Line Noise Protection (continued)
MV Series
Case Styles
MV1 (3, 6, 10A)
D
E
A
C
B
20MV1
D
E
A
C
B
2.00
50.8

 
 
 
Part No.
ABCDE
  



3MV1
    
    
6MV1
    
    
10MV1
    
    
20MV1
    
    
Case Dimensions
Performance Data
Typical Insertion Loss
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
 
     
        
        
        
        
Differential Mode / Symmetrical (Line to Line)

 
 
 
 
     
        
        
        
        
3MV
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
6MV
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
10MV
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
20MV
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0

3MV1

Mfr. #:
Manufacturer:
TE Connectivity
Description:
AC Power Line Filters Power Line Filters .250 3A FILTER
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet