PSA05S Characteristics
WWW.PHIHONG.COM
INPUT:
AC Input Voltage Rating
100 to 240VAC
AC Input Voltage Range
90 to 264VAC
AC Input Current
0.15A(RMS) max.
Leakage Current
5μA maximum
Input Power Saving
<30mW max
OUTPUT:
Power
5W Continuous
Efficiency
Meets Level V Efficiency Requirements
No-Load Power Saving
0.03W maximum at 115VAC/230VAC
Hold-up Time
10mS min. @ 120VAC and max. load
Short Circuit Protection
Output may be shorted permanently without
damage
Over-voltage Protection
Output shall not exceed 10V
ENVIRONMENTAL:
Temperature
Operation 0 to +40°C
Non-operation -40 to +85°C
Operation 10 to 90%
Immunity
ESD: EN61000-4-2. Level 4
Surge: EN61000-4-5. Level 3
Harmonic: EN61000-3-2
Flicker: EN61000-3-3
Emissions
FCC Class B
EN55022 Class B
Dielectric Withstand (Hi-pot) Test
Primary to Secondary: 3000VAC, 10mA for 1
minute
Insulation Resistance
Primary to Secondary: 10M ohm 500VDC
MTBF
100K hours minimum at 120VAC, max load
(measured at ambient 25°C)
DC Output Connector
USB A
Dimension Diagram Unit: mm