2809487

PHOENIX CONTACT Deutschland GmbH Page 1 / 5
http://www.phoenixcontact.de Feb 2, 2011
Extract from the online
catalog
C-UFB- 5DC/E-LAN
Order No.: 2809487
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2809487
Attachment plug with surge protection for LAN interfaces, connection:
BNC female/male connector
Commercial data
GTIN (EAN)
4 017918 076436
sales group J401
Pack 10 pcs.
Customs tariff 85363010
Catalog page information Page 121 (TT-2007)
Product notes
WEEE/RoHS-compliant since:
03/01/2008
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
General
Housing material Aluminum
Color black
Standards for air and creepage distances VDE 0110-1
IEC 60664-1: 1992-10
Total surge current (8/20) µs 10 kA
C-UFB- 5DC/E-LAN Order No.: 2809487
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2809487
PHOENIX CONTACT Deutschland GmbH Page 2 / 5
http://www.phoenixcontact.de Feb 2, 2011
Ambient temperature (operation) -40 °C ... 80 °C
Mounting type Connection-specific intermediate plugging
Design Attachment plug
Number of positions 1
Degree of protection IP20
Direction of action Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Width 25.40 mm
Height 93.00 mm
Length 25.40 mm
Protective circuit
IEC category C2
C3
D1
VDE requirement class C2
C3
D1
Maximum continuous voltage UC (wire-wire) - 7.5 V DC (core-shield)
Maximum continuous voltage U
C
(wire-shield) 0.5 V DC (- 7.5 V DC)
Nominal current I
N
500 mA (25°C)
Operating effective current I
C
at U
C
≤ 100 µA
Ground conductor current I
PE
≤ 1 µA
Nominal discharge surge current I
n
(8/20) µs
(Core-Earth)
10 kA
Nominal discharge surge current I
n
(8/20) µs
(Core-Shield)
10 kA
Nominal discharge surge current I
n
(8/20) µs
(Shield-Earth)
10 kA
Total surge current (8/20) µs 10 kA
Output voltage limitation at 1 kV/µs (Core-Earth)
spike
≤ 600 V
Output voltage limitation at 1 kV/µs (Core-Core)
static
≤ 12 V
Output voltage limitation at 1 kV/µs (Core-Earth)
static
≤ 600 V
Residual voltage at I
n
, (conductor-conductor) ≤ 25 V
Residual voltage at I
n
, (conductor-ground) ≤ 400 V
Protection level U
P
(Core-Core) ≤ 25 V (core-shield)
C-UFB- 5DC/E-LAN Order No.: 2809487
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2809487
PHOENIX CONTACT Deutschland GmbH Page 3 / 5
http://www.phoenixcontact.de Feb 2, 2011
Protection level U
P
(Core-Earth) ≤ 600 V
Response time tA (Core-Core) ≤ 1 ns
Response time tA (Core-Earth) ≤ 100 ns
Input attenuation aE, asym. 0.3 dB (≤ 40 MHz / 50 Ω)
Cut-off frequency fg (3 dB), asym. (PE) in 100
Ohm system
Typ. 200 MHz (50 Ω / core shield)
Cut-off frequency fg (3 dB), asym. (shield) in 100
Ohm system
Typ. 200 MHz (50 Ω)
Capacity (Core-GND) 25 pF (f =1 MHz / V
R
= 0 V)
Resistance in series 2.35 Ω ±10 %
Surge carrying capacity in acc. with IEC 61643-21
(Core-Core)
C2 (10 kV/5 kA)
Surge carrying capacity in acc. with IEC 61643-21
(Core-Earth)
C2 (10 kV/5 kA)
D1 (2.5 kA)
Connection data
Type of connection BNC 50 Ω
Connection type IN BNC socket
Connection type OUT BNC plug
Connection, protective circuit
Standards/regulations IEC 61643-21
Certificates / Approvals
Certification GOST

2809487

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Surge Suppressors C-UFB- 5DC/E-LAN LAN BNC F-M 50