Data Sheet ADuM1210
Rev. D | Page 9 of 20
PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input-to-Output)
1
R
I-O
10
12
Ω
Capacitance (Input-to-Output)
1
C
I-O
1.0 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance
Side 1
θ
JCI
46 °C/W Thermocouple located at center of package underside
Side 2 θ
JCO
41 °C/W
1
The device is considered a 2-terminal device; Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM1210 is approved by the organizations listed in Table 5. See Table 10 and the Insulation Lifetime section for recommended
maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL CSA VDE
Recognized Under 1577
Component Recognition
Program
1
Approved under CSA Component Acceptance Notice #5A
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12
2
Single/Basic 2500 V rms
Isolation Voltage
Basic insulation per CSA 60950-1-03 and IEC 60950-1, 400 V rms
(566 peak) maximum working voltage
Functional insulation per CSA 60950-1-03 and IEC 60950-1,
800 V rms (1131 V peak) maximum working voltage
Reinforced insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM1210 is proof-tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 μA).
2
In accordance with DIN V VDE V 0884-10, each ADuM1210 is proof-tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection
limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 4.90 min mm
Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 4.01 min mm
Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
ADuM1210 Data Sheet
Rev. D | Page 10 of 20
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12 INSULATION CHARACTERISTICS
This isolator is suitable for reinforced isolation within the safety limit data only. Maintenance of the safety data is ensured by protective
circuits. Note that the asterisk (*) marked on the package denotes DIN V VDE V 0884-10 approval for a 560 V peak working voltage.
Table 7.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage, Method B1
V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Input-to-Output Test Voltage, Method A V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1 896 V peak
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
4000 V peak
Safety-Limiting Values
Maximum value allowed in the event of a failure;
see Figure 2
Case Temperature T
S
150 °C
Side 1 Current I
S1
160 mA
Side 2 Current I
S2
170 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
200
180
100
80
60
40
20
50 100 150 200
SIDE #1
SIDE #2
05459-002
120
140
160
Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values
on Case Temperature, per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter Symbol Min Max Unit
Operating Temperature T
A
−40 +105 °C
Supply Voltages
1
V
DD1
, V
DD2
2.7 5.5 V
Input Signal Rise and Fall Times 1.0 ms
1
All voltages are relative to their respective ground. See the
section for information on immunity to external
magnetic fields.
DC Correctness and
Magnetic Field Immunity
Data Sheet ADuM1210
Rev. D | Page 11 of 20
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 9.
Parameter Rating
Storage Temperature (T
ST
) Range −55°C to +150°C
Ambient Operating Temperature
(T
A
) Range
−40°C to +105°C
Supply Voltages (V
DD1
, V
DD2
)
1
−0.5 V to +7.0 V
Input Voltage (V
IA
, V
IB
)
1
−0.5 V to V
DDI
+ 0.5 V
Output Voltage (V
OA
, V
OB
)
1
−0.5 V to V
DDO
+ 0.5 V
Average Output Current, Per Pin (I
O
)
2
−35 mA to +35 mA
Common-Mode Transients (CM
L
, CM
H
)
3
−100 kV/μs to +100 kV/μs
1
All voltages are relative to their respective ground.
2
See Figure 2 for maximum rated current values for various temperatures.
3
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum rating may cause
latch-up or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Table 10. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar Waveform 565 V peak
50-year minimum lifetime
AC Voltage, Unipolar Waveform
Functional Insulation 1131 V peak
Maximum approved working voltage per IEC 60950-1
Basic Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
DC Voltage
Functional Insulation 1131 V peak
Maximum approved working voltage per IEC 60950-1
Basic Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.

ADUM1210BRZ-RL7

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators Digital Dual-CH
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet