I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
2
R04
CPC1394
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
Parameter Ratings Units
Peak Blocking Voltage 600 V
P
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation
1
100 mW
Total Package Dissipation
2
550 mW
Isolation Voltage, Input to Output 5000 V
rms
Operational Temperature -40 to +85 ºC
Storage Temperature -40 to +125 ºC
1
Derate linearly 1.33mW / ºC
2
Derate linearly 3mW / ºC
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous - I
L
- - 120 mA
rms
/ mA
DC
Peak t=10ms I
LPK
- - ±400 mA
P
On-Resistance
1
I
L
=120mA R
ON
-2635
Off-State Leakage Current V
L
=600V
P
I
LEAK
-- 1 A
Switching Speeds
Turn-On I
F
=5mA, V
L
=10V
(See Timing Diagram)
t
on
- 0.85 5
ms
Turn-Off t
off
- 0.46 3
Output Capacitance I
F
=0mA, V
L
=50V, f=1MHz C
OUT
-50 - pF
Input Characteristics
Input Control Current to Activate
2
I
L
=120mA I
F
- 0.45 2
mA
Input Control Current to Deactivate - I
F
0.2 0.4 -
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Reverse Input Current V
R
=5V I
R
--10 A
Common Characteristics
Input to Output Capacitance V
IO
=0V, f=1MHz C
IO
-3 - pF
1
Measurement taken within 1 second of on-time.
2
For operation at temperatures >60ºC, a minimum LED drive current of 4mA is recommended.
Timing Diagram
10%
90%
t
off
t
on
0 mA
I
L
I
F
0 mA