276 MOS FET Relays G3VM-81LR
■ Absolute Maximum Ratings (Ta = 25°C)
■ Electrical Characteristics (Ta = 25°C)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Symbol Rating Unit Measurement Conditions
Input LED forward current I
F
50 mA
Repetitive peak LED
forward current
I
FP
--- A 100 μs pulses, 100 pps
LED forward current
reduction rate
Δ I
F
/°C −0.5 mA/°CT
a
≥ 25°C
LED reverse voltage V
R
5V
Connection temperature T
j
125 °C
Output Load voltage (AC peak/DC) V
OFF
80 V
Continuous load current I
O
120 mA
ON current reduction rate Δ I
O
/°C −1.2 mA/°CT
a
≥ 25°C
Connection temperature T
j
125 °C
Dielectric strength between input and
output (See note 1.)
V
I-O
1,500 V
rms
AC for 1 min
Ambient operating temperature T
a
−20 to +85 °C With no icing or condensation
Storage temperature T
stg
−40 to +125 °C With no icing or condensation
Soldering temperature --- 260 °C 10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item Symbol
Mini-
mum
Typical
Maxi-
mum
Unit
Measurement
conditions
Input LED forward voltage V
F
1.0 1.15 1.3 V I
F
= 10 mA
Reverse current I
R
--- --- 10 μAV
R
= 5 V
Capacity between terminals C
T
--- 15 --- pF V = 0, f = 1 MHz
Trigger LED forward current I
FT
--- 2 5 mA I
O
= 120 mA
Output Maximum resistance with output ON R
ON
--- 7.5 12 Ω I
F
= 10 mA,
I
O
= 120 mA, t = 10 ms
Current leakage when the relay is open I
LEAK
--- 100 200 pA V
OFF
= 80 V, T
a
= 60°C
Capacity between terminals C
OFF
--- 5 7 pF V = 0, f = 100 MHz,
t < 1 s
Capacity between I/O terminals C
I-O
--- 0.8 --- pF f = 1 MHz, V
s
= 0 V
Insulation resistance between I/O terminals R
I-O
1,000 --- --- MΩ V
I-O
= 500 VDC,
R
oH
≤ 60%
Tu r n - O N t i m e t
ON
--- 0.1 0.25 ms I
F
= 10 mA, R
L
= 200 Ω,
V
DD
= 20 V (See note 2.)
Turn-OFF time t
OFF
--- 0.15 0.2 ms
VOUT
IF
tON tOFF
10%
90%
IF
1
2
4
3
RL
VDD
VOUT
Note: 2. Turn-ON and Turn-OFF
Times
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) V
DD
--- --- 64 V
Operating LED forward current I
F
10 --- 30 mA
Continuous load current (AC peak/DC) I
O
--- --- 120 mA
Operating temperature T
a
25 --- 60 °C