June 2014 DocID5202 Rev 8 1/11
11
FLC10
Fire lighter circuit
Datasheet − production data
Features
• Dedicated thyristor structure for capacitance
discharge ignition operation
• High pulse current capability:
– 240 A at t
p
= 10 µs
• Fast turn-on operation
• Designed for high ambient temperature
(up to 120° C)
Benefits
• Space saving thanks to monolithic function
integration
• High reliability with planar technology
Description
The FLC10 series has been especially developed
for high power capacitance discharge operation.
The main applications are gas lighters or ignitors
such as cookers / gas boilers / gas hobs...
It provides a fully integrated function, with high
performance and reliability levels, adapted to
severe and hot temperature environment.
– Th: Thyristor for switching operation
– Z: Zener diode to set the threshold voltage
– D: Diode for reverse conduction
– R: 2 k
Ω resistor
Figure 1. Functional diagram
IPAK
1
1
TAB
TAB
2
2
DPAK
3
3
Z
R
D
Th
pin 2 (or tab)
pin 1/3 *
* Pin1 and pin3 must be shorted together
in the application circuit layout