PRELIMINARY
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC75282
4 PRELIMINARY R00E
1.4 Absolute Maximum Ratings
Absolute maximum electrical ratings are at 25qC.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.5 ESD Rating
1.6 General Conditions
Unless otherwise specified, minimum and maximum
values are production testing requirements. Typical
values are characteristic of the device and are the
result of engineering evaluations. They are provided
for information purposes only and are not part of the
testing requirements.
Specifications cover the operating temperature range
T
A
= -40qC to +85qC. Also, unless otherwise specified,
all testing is performed with V
DD
= 5V
DC
, logic low
input voltage is 0V
DC
and logic high voltage is 5V
DC
.
Parameter Minimum Maximum Unit
+5V power supply (V
DD
)
-0.3 7 V
Battery Supply - -85 V
D
GND
to F
GND
Separation
-5 +5 V
Logic input voltage -0.3
V
DD
+ 0.3
V
Logic input to switch output
isolation
-320V
Switch open-contact
isolation (SW1, SW2, SW3,
SW5, SW6)
-320V
Switch open-contact
Isolation (SW4)
-465V
Operating relative humidity 5 95 %
Operating temperature -40 +110 qC
Storage temperature -40 +150 qC
ESD Rating (Human Body Model)
1000V
PRELIMINARY
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC75282
R00E PRELIMINARY 5
1.7 Switch Specifications
1.7.1 Break Switches, SW1 and SW2
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Off-State
Leakage Current
V
SW1
(differential) = T
LINE
to T
BAT
V
SW2
(differential) = R
LINE
to R
BAT
All-Off state.
+25qC,
V
SW
(differential) = -320V to gnd
V
SW
(differential) = +260V to -60V
I
SW
--1PA
+85q C,
V
SW
(differential) = -330V to gnd
V
SW
(differential) = +270V to -60V
-40qC,
V
SW
(differential) = -310V to gnd
V
SW
(differential) = +250V to -60V
On Resistance
I
SW
(on) = ±10mA, ±40mA,
R
BAT
and T
BAT
= -2V
+25qC
R
ON
-
14.5 -
:+85qC-31
-40qC10.5-
On Resistance
Matching
Per SW1 & SW2 On Resistance test
conditions.
'R
ON
- 0.02 1.0 :
ON-State Voltage
1
Maximum Differential Voltage (V
max
)
'V
ON
- - 320
V
Foldback Voltage Breakpoint 1 (V
1
)
60 - -
Foldback Voltage Breakpoint 2 (V
2
)V
1
+ 0.5
--
DC current limit 1 (I
LIM1
)
V
SW
(on) = ±10V, +25qC
I
SW
- 300
mA
V
SW
(on) = ±10V, +85qC
80
V
SW
(on) = ±10V, -40qC
- 425
DC current limit 2 (I
LIM
2) I
SW
1--
Dynamic current limit
(t = <0.5 Ps)
Break switches on, all other switches
off. Apply ±1 kV 10x1000 Ps pulse with
appropriate protection in place.
I
SW
-2.5- A
Logic Input to Switch
Output Isolation
+25q C, OFF
x
= 0,
V
SW
(T
LINE
, R
LINE
) = ±320V
I
SW
--
1 PA
+85q C, OFF
x
= 0,
V
SW
(T
LINE
, R
LINE
) = ±330V
--
-40q C, OFF
x
= 0,
V
SW
(T
LINE
, R
LINE
) = ±310V
--
Transient Immunity
2
dV/dt 1500 2100 - V/Ps
1
Choice of secondary protector should ensure this rating is not exceeded.
2
Applied voltage is 100V
P-P
square wave at 100Hz.
PRELIMINARY
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC75282
6 PRELIMINARY R00E
1.7.2 Ringing Return Switch, SW3
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Off-State
Leakage Current
V
SW3
(differential) = T
LINE
to T
RINGING
All-Off state.
+25q C,
V
SW
(differential) = -320V to gnd
V
SW
(differential) = +260V to -60V
I
SW
-
-
1 PA
+85q C,
V
SW
(differential) = -330V to gnd
V
SW
(differential) = +270V to -60V
-
-40q C,
V
SW
(differential) = -310V to gnd
V
SW
(differential) = +250V to -60V
-
On Resistance
I
SW
(on) = ±0mA, ±10mA, +25qC
R
ON
-
60 -
:
I
SW
(on) = ±0mA, ±10mA, +85qC
85 100
I
SW
(on) = ±0mA, ±10mA, -40qC
45 -
ON-State Voltage
1
Maximum Differential Voltage (V
max
)
'V
ON
- - 320
V
Foldback Voltage Breakpoint 1 (V
1
)
200 - -
Foldback Voltage Breakpoint 2 (V
2
)V
1
+ 0.5
--
DC current limit 1 (I
LIM1
)
V
SW
(on) = ±10V, +25qC
I
SW
- 135
-
mA
V
SW
(on) = ±10V, +85qC
70 85
V
SW
(on) = ±10V, -40qC
- 210
DC current limit 2 (I
LIM2
)
1--
Dynamic current limit
(t = <0.5 Ps)
Ringing switches on, all other switches
off. Apply ±1kV 10x1000 Ps pulse with
appropriate protection in place.
I
SW
-2.5- A
Logic Input to Switch
Output Isolation
+25qC, OFF
x
= 0,
V
SW
(T
RINGING
, T
LINE
) = ±320V
I
SW
-
-
1 PA
+85qC, OFF
x
= 0,
V
SW
(T
RINGING
, T
LINE
) = ±330V
-
-40qC, OFF
x
= 0,
V
SW
(T
RINGING
, T
LINE
) = ±310V
-
Transient Immunity
2
- dV/dt 1500 2100 - V/Ps
1
This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.
2
Applied voltage is 100V