PRELIMINARY
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC75282
4 PRELIMINARY R00E
1.4 Absolute Maximum Ratings
Absolute maximum electrical ratings are at 25qC.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.5 ESD Rating
1.6 General Conditions
Unless otherwise specified, minimum and maximum
values are production testing requirements. Typical
values are characteristic of the device and are the
result of engineering evaluations. They are provided
for information purposes only and are not part of the
testing requirements.
Specifications cover the operating temperature range
T
A
= -40qC to +85qC. Also, unless otherwise specified,
all testing is performed with V
DD
= 5V
DC
, logic low
input voltage is 0V
DC
and logic high voltage is 5V
DC
.
Parameter Minimum Maximum Unit
+5V power supply (V
DD
)
-0.3 7 V
Battery Supply - -85 V
D
GND
to F
GND
Separation
-5 +5 V
Logic input voltage -0.3
V
DD
+ 0.3
V
Logic input to switch output
isolation
-320V
Switch open-contact
isolation (SW1, SW2, SW3,
SW5, SW6)
-320V
Switch open-contact
Isolation (SW4)
-465V
Operating relative humidity 5 95 %
Operating temperature -40 +110 qC
Storage temperature -40 +150 qC
ESD Rating (Human Body Model)
1000V