1.3 Absolute Maximum Ratings
Absolute maximum electrical ratings are at 25C.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.4 General Conditions
Unless otherwise specified, minimum and maximum
values are guaranteed by production testing. Typical
values are characteristic of the device and are the
result of engineering evaluations. They are provided
for informational purposes only and are not
guaranteed by production testing.
Specifications cover the operating temperature range
T
A
= -40C to +85C. Also, unless otherwise specified,
all testing is performed with V
DD
= 3.3V
DC
, logic low
input voltage is 0V
DC
and logic high input voltage is
3.3V
DC
.
Parameter Minimum Maximum Unit
+3.3V power supply (V
DD
)
-0.3 + 7 V
Logic input voltage -0.3
V
DD
+ 0.3
V
Logic input to switch output
isolation
-320V
Switch open-contact isolation
(SW1, SW2, SW3, SW4)
-320V
Operating relative humidity 5 95 %
Operating temperature -40 +110 C