DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP08-A
Series
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range
without derating
with derating
-40°C to +80°C
-40°C to +100°C
Maximum Case Temperature +100°C
Temperature Coefficient ±0.02%/°C max.
Thermal Impedance Natural convection (20LFM) 20°C/Watt typ.
Operating Humidity non-condensing 5% - 95% RH
Shock MIL-STD-810F
Vibration MIL-STD-810F
MTBF
MIL-HDBK-217F
BELLCORE TR-NWT-000332
(7)
3543 x 10
3
hours
3165 x 10³ hours
Notes:
Note7: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here
please contact our technical support service at techsupportAT@recom-power.com.
-40 60 80
10040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
Derating Graph
(8)
RP08-1212SA
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Over Load Protection (OLP) % of Iout rated 150% typ.
Isolation Voltage
DIP24
I/P to O/P
I/P (O/P) to case
1.6kVDC/1 minute
1.6kVDC/1 minute
SMD
I/P to O/P
I/P (O/P) to case
1.6kVDC/1 minute
1.0kVDC/1 minute
Isolation Resistance 500VDC 1GΩ min.
Isolation Capacitance 300pF max.
Notes:
Note6: This power module is not internally fused. An input line fuse must always be used.
PD-4