1-866-9-OHMITE • Int’l 1-847-258-0300 • Fax 1-847-574-7522 • www.ohmite.com • info@ohmite.com
138
CHARACTERISTICS
TAP650 Series
High-power, low profile design
Derating
Percent rated power
Bottom of base plate Temperature, °C
0255075 100 125 150 175
40
0
60
80
120
20
100
Rated power, watts
260
0
390
520
780
130
650
FEATURES
•Forvariablespeeddrives,powersupplies,control
devices,robotics,motorcontrolandotherpower
designs.
•High-purityceramicmetalizedwithfilmonbottomfor
betterheattransferandoptimumdischarge.
•Encapsulation:Specialresin-filledepoxycasing.
Highinsulationresistance(CTI600),highdielectric
strengthandpartialdischargecapability.
•ResistanceElement:Specialdesignforlowinductance
andcapacitancevalues.Theelementdemonstrates
stabilitywhilecoveringhighwattageandpulseload-
ing.
(continued)
Resistance values
0.25Ω to 1MΩ (others upon request).
Values below 1 ohm are measured at
max lead length.
Resistance tolerance
±5% to ±10%
Temperature coefficient
±150 ppm/°C (others upon request)
Maximum working
voltage
5,000VDC, higher voltage upon request,
not exceeding max. power
Short time overload
1,000 W at 70°C for 10sec., delta-R =
0.4% max.
Power rating
650W at 85°C bottom case temperature
(others upon request)
Peak current
up to 1,500A depending on pulse length
and frequency. Please ask for details!
Electric strength voltage
6kVrms, 50 Hz,up to 12 kVrms upon
special request.
Single shot voltage
up to 12kV norm wave (1.5/50 µsec)
Partial discharge
4KVrms, <10 pC, up to 7kV upon spe-
cial request
Insulation resistance
10 GΩ min. at 500V
Inductance
80nH (typical)
Capacity/mass
110 pF
Capacity/parallel
40 pF
Operating temperature
res. body: -55°C to +150°C; std. cables:
-40°C to +120°C (other cables upon
request)
Mounting max. torque
1.8 Nm, M4 screws
Housing material
According to UL94-V0
Standard storage condi-
tions
0° to 85°C at 80% RH max. for min. 12
months. For different conditions please
contact factory
Derating (thermal resist.)
8.55W/°K (0.117°K/W)
Power
rating
650W at 85°C bottom case temp. (Please ask for detailed
mounting procedure! This value is only applicable if using
thermal conduction to the heat sink Rth-cs<0.117°K/W.
This value can be obtained by using a thermal transfer
compound with a heat conductivity of 8.55 W/mK. The
flatness of the cooling plate must be better than 0.05mm
overall. Surface roughness should not exceed 6.4µm.
Test
Method
Typical
results
Short time overload
1,000W/10sec 0.4%
Humidity steady state
56 days/40°C/95% 0.25%
Temp. cycling
-55°/+125°/5 cycles 0.20%
Shock
40g/4,000 times 0.25%
Vibrations
2-500Hz/10g 0.25%
Load life
3,000cyl; Pn 30 min. on /
30 min off
0.40%