NB4N121K
http://onsemi.com
5
Table 5. AC CHARACTERISTICS V
CC
= 3.0 V to 3.6 V, GND = 0 V; −40°C to +70°C (Note 7)
Symbol
Characteristic Min Typ Max Unit
V
OUTPP
Output Voltage Amplitude (@ V
INPPmin
) f
in
= 133 MHz
f
in
= 166 MHz
f
in
= 200 MHz
725
725
725
900
900
900
mV
t
PLH
,
t
PHL
Propagation Delay to (See Figure 3) CLK/CLK to Qx/Qx 550 800 950 ps
Dt
PLH
,
Dt
PHL
Propagation Delay Variations Variation Per Each Diff Pair CLK/CLK to Qx/Qx
(Note 8) (See Figure 3)
100 ps
t
SKEW
Duty Cycle Skew (Note 9)
Within−Device Skew, 1X Mode Only (Note 10)
Within−Device Skew, 2X Mode (Note 10)
Device−to−Device Skew (Note 10)
20
50
80
150
ps
ps
ps
ps
t
jit(
f
)
Additive RMS Phase RMS (Note 11) f
in
=133 MHz to 200 MHz 1 ps
V
cross
Absolute Crossing Magnitude Voltage 250 550 mV
DV
cross
Variation in Magnitude of V
cross
150 mV
t
r
, t
f
Absolute Magnitude in Output Risetime and Falltime Qx, Qx
(From 175 mV to 525 mV)
175 340 700 ps
Dt
r,
Dt
f
Variation in Magnitude of Risetime and Falltime (Single−Ended) Qx, Qx
(See Figure 4)
1X
2X
125
150
ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
7. Measured by forcing V
INPP
(MIN) from a 50% duty cycle clock source. Measurements taken with outputs in either 1X (all outputs loaded
50 W to GND) or 2X (all outputs loaded 25 W to GND) configuration, see Figure 9. For 1X configuration, connect I
REF
to GND, or for 2X
configuration, connect I
REF
to V
CC
. Typical gain is 20 dB.
8. Measured from the input pair crosspoint to each single output pair crosspoint across temp and voltage ranges.
9. Duty cycle skew is measured between differential outputs using the deviations of the sum of Tpw− and Tpw+.
10.Skew is measured between outputs under identical transition @ 133 MHz.
11. Additive RMS jitter with 50% duty cycle clock signal using phase noise integrated from 12 KHz to 33 MHz
Figure 3. AC Reference Measurement
CLK
CLK
Q
Q
t
PLH
t
PHL
V
INPP
= V
IH
(CLK) − V
IL
(CLK)
= V
IH
(CLK) − V
IL
(CLK)
V
OUTPP
= V
OH
(Q) − V
OL
(Q)
= V
OH
(Q) − V
OL
(Q)
Dt
PLH
Dt
PHL