21
FN8118.3
December 9, 2015
V
TRIP
Programming Specifications: V
CC
= 2.0-5.5V; Temperature = 25°C
ABOUT INTERSIL
Intersil Corporation is a leading provider of innovative power management and precision analog solutions. The company's products
address some of the largest markets within the industrial and infrastructure, mobile computing and high-end consumer markets.
For the most updated datasheet, application notes, related documentation and related parts, please see the respective product
information page found at www.intersil.com.
You may report errors or suggestions for improving this datasheet by visiting www.intersil.com/ask.
Reliability reports are also available from our website at www.intersil.com/support
Parameter Description Min. Max. Unit
t
VPS
WP Program Voltage Setup time 10 µs
t
VPH
WP Program Voltage Hold time 10 µs
t
TSU
V
TRIP
Level Setup time 10 µs
t
THD
V
TRIP
Level Hold (stable) time 10 µs
t
WC
V
TRIP
Program Cycle 10 ms
t
VPO
Program Voltage Off time before next cycle 1 ms
V
P
Programming Voltage 15 18 V
V
TRAN
V
TRIP
Set Voltage Range 2.0 4.75 V
V
tv
V
TRIP
Set Voltage variation after programming (-40 to +85°C). -25 +25 mV
t
VPS
WP Program Voltage Setup time 10 µs
REVISION HISTORY
The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to the web to make sure that
you have the latest revision.
DATE REVISION CHANGE
December 9, 2015 FN8118.3 Updated Ordering Information Table on page 2.
Added Revision History and About Intersil sections.
X4043, X4045