Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
R
I-O
10
12
Capacitance (Input to Output)
1
C
I-O
1.0 pF f = 1 MHz
Input Capacitance C
I
4.0 pF
IC Junction to Case Thermal Resistance, Side 1 θ
JCI
46 °C/W Thermocouple located at center
of package underside
IC Junction to Case Thermal Resistance, Side 2 θ
JCO
41 °C/W
1
The device is considered a 2-terminal device; Pin 1, Pin 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
REGULATORY INFORMATION
The ADuM3200-EP/ADuM3201-EP devices are pending approval by the organizations listed in Table 14. Refer to Table 19 for details
regarding recommended maximum working voltages for specific cross isolation waveforms and insulation levels.
Table 14.
UL (Pending) CSA (Pending) VDE (Pending)
Recognized Under UL 1577 Component
Recognition Program
1
Approved under CSA Component Acceptance Notice 5A Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
Single/Basic 2500 V rms Isolation Voltage Basic insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (566 V
PEAK
) maximum working voltage
Reinforced insulation, 560 V
PEAK
Functional insulation per CSA 60950-1-03 and IEC 60950-1,
800 V rms (1131 V
PEAK
) maximum working voltage
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM3200-EP/ADuM3201-EP is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10, each ADuM3200-EP/ADuM3201-EP is proof tested by applying an insulation test voltage ≥1050 V
PEAK
for 1 sec (partial discharge
detection limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 15.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Tracking (Creepage) L(I02) 4.0 mm min Measured from input terminals to output terminals,
shortest distance path along package body
Minimum External Air Gap (Clearance)
L(I01)
4.0
mm min
Measured from input terminals to output terminals,
shortest distance through air
Minimum Clearance in the Plane of the Printed
Circuit Board (PCB Clearance)
L(PCB) 4.0
1
mm min Measured from input terminals to output terminals,
shortest distance through air, line of sight, in the PCB
mounting plane
Minimum Internal Gap (Internal Clearance) 0.017 mm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
Isolation Group II Material group (DIN VDE 0110, 1/89, Table 1)
1
This value is for information only, to aid in PCB design. Package clearance is identical to creepage as specified in L(I02).
ADuM3200-EP/ADuM3201-EP Enhanced Product
Rev. B | Page 8 of 12
INSULATION CHARACTERISTICS (DIN V VDE V 0884-10 (VDE V 0884-10):2006-12)
These isolators are suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by protective
circuits. The asterisk (*) marking on the package denotes DIN V VDE V 0884-10 approval for a 560 V
PEAK
working voltage.
Table 16.
Description Test Conditions/Comments Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/125/21
Pollution Degree per DIN VDE 0110, Table 1
2
Maximum Working Insulation Voltage V
IORM
560 V
PEAK
Input to Output Test Voltage, Method B1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V
PEAK
Input to Output Test Voltage, Method A V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1 896 V
PEAK
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V
PEAK
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 sec V
TR
4000 V
PEAK
Surge Isolation Voltage V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs, 50% fall time V
IOSM
4000 V
PEAK
Safety Limiting Values Maximum value allowed in the event of a failure
(see Figure 3)
Case Temperature T
S
150 °C
Total Power Dissipation at 25°C P
S
1.56 W
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
CASE TEMPERATURE (°C)
SAFETY LIMITING CURRENT (mA)
0
0
200
180
100
80
60
40
20
50 100 150 200
SIDE 1
SIDE 2
120
140
160
13088-003
Figure 3. Thermal Derating Curve, Dependence of Safety Limiting Values
on Case Temperature, per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 17.
Parameter Symbol Min Max Unit
Operating Temperature T
A
55 +125 °C
Supply Voltages
1
V
DD1
, V
DD2
3.0
5.5
V
Maximum Input Signal Rise and
Fall Times
1.0 ms
Start-Up Current I
DD1
, I
DD2
20 mA
1
All voltages are relative to their respective ground.
Enhanced Product ADuM3200-EP/ADuM3201-EP
Rev. B | Page 9 of 12
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 18.
Parameter Rating
Storage Temperature (T
ST
) −55°C to +150°C
Ambient Operating Temperature (T
A
) −55°C to +125°C
Supply Voltages (V
DD1
, V
DD2
)
1
−0.5 V to +7.0 V
Input Voltages (V
IA
, V
IB
)
1, 2
−0.5 V to V
DDI
+ 0.5 V
Output Voltages (V
OA
, V
OB
)
1, 2
−0.5 V to V
DDO
+ 0.5 V
Average Output Current, per Pin (I
O
)
3
−22 mA to +22 mA
Common-Mode Transients (CM
L
, CM
H
)
4
−100 kV/μs to +100 kV/μs
1
All voltages are relative to their respective ground.
2
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides of a
given channel, respectively.
3
See Figure 3 for maximum rated current values for various temperatures.
4
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum ratings can cause latch-up
or permanent damage.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
ESD CAUTION
Table 19. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar Waveform 565 V
PEAK
50-year minimum lifetime
AC Voltage, Unipolar Waveform
Functional Insulation 1131 V
PEAK
Maximum approved working voltage per IEC 60950-1
Basic Insulation 560 V
PEAK
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
DC Voltage
Functional Insulation 1131 V
PEAK
Maximum approved working voltage per IEC 60950-1
Basic Insulation 560 V
PEAK
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1
Refers to continuous voltage magnitude imposed across the isolation barrier.
Table 20. ADuM3200-EP Truth Table (Positive Logic)
V
IA
Input V
IB
Input V
DD1
State V
DD2
State V
OA
Output V
OB
Output Notes
High High Powered Powered High High
Low Low Powered Powered Low Low
High Low Powered Powered High Low
Low High Powered Powered Low High
X
1
X
1
Unpowered Powered High High
Outputs return to the input state within
1 μs of V
DDI
power restoration.
X
1
X
1
Powered Unpowered Indeterminate Indeterminate
Outputs return to the input state within
1 μs of V
DDO
power restoration.
1
X means don’t care.
Table 21. ADuM3201-EP Truth Table (Positive Logic)
V
IA
Input V
IB
Input V
DD1
State V
DD2
State V
OA
Output V
OB
Output Notes
High High Powered Powered High High
Low Low Powered Powered Low Low
High Low Powered Powered High Low
Low High Powered Powered Low High
X
1
X
1
Unpowered Powered Indeterminate High
Outputs return to the input state within
1 μs of V
DDI
power restoration.
X
1
X
1
Powered Unpowered High Indeterminate
Outputs return to the input state within
1 μs of V
DDO
power restoration.
1
X means don’t care.

ADUM3200TRZ-EP

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators DUAL-CHANNEL DIGITAL ISOLATORS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union