ABSOLUTE MAXIMUM RATING (Ta=25C)
PARAMETER SYMBOL
RATINGS UNIT
Supply Voltage V
+
14 V
Power Dissipation P
D
320(TVSP10)
300(SSOP14)
mW
Operating Temperature Range T
opr
-20 to +75 C
Storage Temperature Range T
stg
-40 to +125 C
ELECTRICAL CHARACTERISTICS
POWER SUPPLY (Ta=25C, V
+
=5V unless otherwise specified)
PARAMETER SYMBOL
TEST CONDITION MIN. TYP. MAX. UNIT
Operating Voltage V
+
- 2.7 5.0 13.0 V
Operating Current I
CC
No Signal - 1.5 2.0 mA
Reference Voltage Vref No Signal 2.2 2.5 2.7 V
AC CHARACTERISTICS
(Ta=25C, V
+
=5V, V
IN
=1Vrms/f=1kHz, Rsense=20k, BW=400-30kHz unless otherwise specified)
PARAMETER SYMBOL
TEST CONDITION MIN.
TYP. MAX. UNIT
Limit Level 1 G
LIM1
150 200 250 mVrms
Limit Level 2 G
LIM2
V
+
=13V,Rsense=4k,V
IN
=2Vrms
0.7 1.0 1.3 Vrms
Limit Off G
OFF
SW=2V 0.9 1.0 1.1 Vrms
Output Noise V
NO
R
S
=0, A-weighting,
-
-100
(10)
-90
(31.6)
dBV
(Vrms)
Total Harmonic Distortion THD+N - - 1 %
Cross Talk CT - - -70 dB
Ripple Rejection RR V
ripple
=100mVrms, f=1kHz - -
-70
(316)
dBV
(Vrms)
CONTROL CHARACTERISTICS (Ta=25C, V
+
=5V unless otherwise specified)
PARAMETER SYMBOL
TEST CONDITION MIN. TYP. MAX. UNIT
Low Level Input Voltage V
IL
- - - 0.5 V
High Level Input Voltage V
IH
- 2.0 - - V
CONTROL TERMINAL EXPLANATION
SW(TVSP10:7pin, SSOP14:11pin)
MODE STATUS
NOTE
Limiter ON L Limiter is active.
Limiter OFF H Limiter is not active.