Description
These Precision Optical Performance AlInGaP LEDs provide
superior light output for excellent readability in sunlight
and are extremely reliable. AlInGaP LED technology pro-
vides extremely stable light output over long periods of
time. Precision Optical Performance lamps utilize the alumi-
num indium gallium phosphide (AlInGaP) technology.
These LED lamps are untinted, nondiused, T-1
3
/
4
pack-
ages incorporating second generation optics producing
well dened spatial radiation patterns at specic viewing
cone angles.
These lamps are made with an advanced optical grade
epoxy, oering superior high temperature and high mois-
ture resistance performance in outdoor signal and sign
applications. The high maximum LED junction tempera-
ture limit of +130°C enables high temperature operation
in bright sunlight conditions. The package epoxy contains
both uv-a and uv-b inhibitors to reduce the eects of long
term exposure to direct sunlight.
These lamps are available in two package options to give
the designer exibility with device mounting.
Benets
Viewing angles match trac management sign require-
ments
Colors meet automotive and pedestrian signal speci-
cations
Superior performance in outdoor environments
Suitable for autoinsertion onto PC boards
Features
Well dened spatial radiation patterns
Viewing angles: 8°, 15°, 23°, 30°
High luminous output
Colors:
590 nm amber
605 nm orange
615 nm reddish-orange
626 nm red
High operating temperature: T
J
led = +130°C
Superior resistance to moisture
Package options:
With or without lead stand-os
Applications
Trac management:
Trac signals
Pedestrian signals
Work zone warning lights
Variable message signs
Commercial outdoor advertising:
Signs
Marquees
Automotive:
Exterior and interior lights
HLMP-ELxx, HLMP-EHxx, HLMP-EJxx, HLMP-EGxx
T-1
3
/
4
(5 mm) Precision Optical Performance
AlInGaP LED Lamps
Data Sheet
2
Device Selection Guide
Typical Color and Dominant Lamps without Lamps with Standos Luminous Intensity
Viewing Angle Wavelength Standos on Leads on Leads Iv (mcd)
[1,2,5]
@ 20 mA
2θ
1
/
2
(Deg.)
[4]
(nm), Typ.
[3]
(Outline Drawing A) (Outline Drawing B) Min. Max.
Amber 590 HLMP-EL08-T0000 HLMP-EL10-T0000 2500
HLMP-EL08-VY000 HLMP-EL10-VY000 4200 12000
HLMP-EL08-VYK00 4200 12000
HLMP-EL08-WZ000 HLMP-EL10-WZ000 5500 16000
HLMP-EL08-X1K00 HLMP-EL10-X1K00 7200 21000
HLMP-EL08-X1000 HLMP-EL10-X1000 7200 21000
Orange 605 HLMP-EJ08-WZ000 5500 16000
HLMP-EJ08-X1000 HLMP-EJ10-X1000 7200 21000
HLMP-EJ08-Y2000 9300 27000
Red-Orange 615 HLMP-EH08-UX000 HLMP-EH10-UX000 3200 9300
HLMP-EH08-WZ000 HLMP-EH10-WZ000 5500 16000
HLMP-EH08-X1000 HLMP-EH10-X1000 7200 21000
HLMP-EH08-Y2000 HLMP-EH10-Y2000 9300 27000
Red 626 HLMP-EG08-T0000 HLMP-EG10-T0000 2500
HLMP-EG08-VY000 4200 12000
HLMP-EG08-WZ000 HLMP-EG10-WZ000 5500 16000
HLMP-EG08-X1000 HLMP-EG10-X1000 7200 21000
HLMP-EG08-YZ000 9300 16000
HLMP-EG08-Y2000 HLMP-EG10-Y2000 9300 27000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ
1/2
is the o-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each intensity bin limit is ± 15%.
3
Device Selection Guide
Typical Color and Dominant Lamps without Lamps with Standos Luminous Intensity
Viewing Angle Wavelength Standos on Leads on Leads Iv (mcd)
[1,2,5]
@ 20 mA
2θ
1
/
2
(Deg.)
[4]
(nm), Typ.
[3]
(Outline Drawing A) (Outline Drawing B) Min. Max.
15° Amber 590 HLMP-EL17-M0000 520
HLMP-EL15-PS000 880 2500
HLMP-EL15-QSK00 1150 2500
HLMP-EL15-QT000 1150 3200
HLMP-EL15-RU000 1500 4200
HLMP-EL15-TW000 HLMP-EL17-TW000 2500 7200
HLMP-EL15-TWK00 2500 7200
HLMP-EL15-UX000 HLMP-EL17-UX000 3200 9300
HLMP-EL15-VY000 HLMP-EL17-VY000 4200 12000
HLMP-EL15-VYK00 4200 12000
HLMP-EL15-VW000 4200 7200
Orange 605 HLMP-EJ17-QT000 1150 3200
HLMP-EJ15-PS000 880 2500
HLMP-EJ15-RU000 1500 4200
HLMP-EJ15-SV000 HLMP-EJ17-SV000 1900 5500
Red-Orange 615 HLMP-EH15-QT000 1150 3200
HLMP-EH15-RU000 1500 4200
HLMP-EH15-TW000 HLMP-EH17-TW000 2500 7200
HLMP-EH15-UX000 HLMP-EH17-UX000 3200 9300
Red 626 HLMP-EG15-N0000 HLMP-EG17-N0000 680
HLMP-EG15-PS000 880 2500
HLMP-EG15-QT000 HLMP-EG17-QT000 1150 3200
HLMP-EG15-RU000 HLMP-EG17-RU000 1500 4200
HLMP-EG15-UX000 HLMP-EG17-UX000 3200 9300
HLMP-EG15-TW000 HLMP-EG17-TW000 2500 7200
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength, λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4. θ
1/2
is the o-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each intensity bin limit is ± 15%.

HLMP-EG30-MQ0DD

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Standard LEDs - Through Hole Red, 626nm 30 Deg, 1500mcd(max)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union