SCX01DNC

Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
SCX Serie
s
FEATURES
Precision Temperature
Compensation
Calibrated Zero & Span
Small Size
Low Noise
Low Cost (SCX_NC)
High Accuracy (SCX_N)
High Impedance for Low
Power Applications
TYPICAL APPLICATIONS
Medical Equipment
The SCX series sensors provide a very cost-effective solution for pressure
applications that require operation over wide temperature range. These
internally calibrated and temperature compensated sensors were specifically
designed to provide an accurate and stable output over a 0 °C to 70 °C
[32 °F to 158 °F] temperature range. This series is intended for use with non-
corrosive, non-ionic working fluids such as air, dry gases and the like.
Barometry
Computer Peripherals
Pneumatic Controls
HVAC
ELECTRICAL CONNECTION
Devices are available to measure absolute, differential and gage pressures
from 1 psi (SCX01) up to 150 psi (SCX150). The Absolute (A in model
number) devices have an internal vacuum reference and an output voltage
proportional to absolute pressure. The Differential (D in model number)
devices allow application of pressure to either side of the pressure-sensing
diaphragm and can be used for gage or differential measurements.
The SCX series devices feature an integrated circuit (IC) sensor element
and laser trimmed thick film ceramic housed in a compact solvent resistant
case. This package provides excellent corrosion resistance and provides
isolation to external packaging stresses. The package has convenient
mounting holes and pressure ports for ease of use with standard plastic
tubing for pressure connection.
PIN 1) TEMPERATURE OUTPUT (+)
PIN 2) Vs
PIN 3) + OUTPUT
PIN 4) GROUND
If the application requires extended temperature range operation, beyond
0 °C to 70 °C [32 °F to 158 °F], two pins which provide an output voltage
proportional to temperature are available for use with external circuitry. The
100 microsecond response time makes this series an excellent choice for
computer peripherals and pneumatic control applications.
PIN 5) - OUTPUT
PIN 6) TEMPERATURE OUTPUT (-)
Note: The polarity indicated is for
pressure applied to port B. (For
absolute devices pressure is applied
to port A and the output polarity is
reversed)
The output of the bridge is ratio metric to the supply voltage. Operation from
any dc supply voltage up to 20 Vdc is acceptable.
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Contact your local honeywell representative, or go to Honeywell’s website at
www.honeywell.com/sensing for additional details.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do not
use this document as a product installation guide.
Complete installation, operation, and maintenance information is provided in
the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious
injury.
Sensing and Control
Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
SCX Serie
s
PRESSURE RANGE SPECIFICATIONS
Full-Scale Span
(1)
Model *
Operating
Pressure
Proof
Pressure
(2)
Sensitivity Min. Typ. Max.
SCX01DN 17.82 mV 18.00 mV 18.18 mV
SCX01DNC
0 psid to 1 psid 20 psid 18 mV/psi
17.00 mV 18.00 mV 19.00 mV
SCX05DN 59.40 mV 60.00 mV 60.60 mV
SCX05DNC
0 psid to 5 psid 20 psid 12 mV/psi
57.50 mV 60.00 mV 62.50 mV
SCX15AN 89.10 mV 90.00 mV 90.90 mV
SCX15ANC
0 psid to 15 psia 30 psia 6.0 mV/psi
85.00 mV 90.00 mV 95.00 mV
SCX15DN 89.10 mV 90.00 mV 90.90 mV
SCX15DNC
0 psid to 15 psid 30 psid 6.0 mV/psi
85.00 mV 90.00 mV 95.00 mV
SCX30AN 89.10 mV 90.00 mV 90.90 mV
SCX30ANC
0 psid to 30 psia 60 psia 3.0 mV/psi
85.00 mV 90.00 mV 95.00 mV
SCX30DN 89.10 mV 90.00 mV 90.90 mV
SCX30DNC
0 psid to 30 psid 60 psid 3.0 mV/psi
85.00 mV 90.00 mV 95.00 mV
SCX100AN 99.00 mV 100.0 mV 101.0 mV
SCX100ANC
0 psid to 100 psia 150 psia 1.0 mV/psi
95.00 mV 100.0 mV 105.0 mV
SCX100DN 99.00 mV 100.0 mV 101.0 mV
SCX100DNC
0 psid to 100 psid 150 psid 1.0 mV/psi
95.00 mV 100.0 mV 105.0 mV
SCX150AN 89.00 mV 90.00 mV 91.00 mV
SCX150ANC
0 psid to 150 psia 150 psia 0.6 mV/psi
85.00 mV 90.00 mV 95.00 mV
SCX150DN 89.00 mV 90.00 mV 91.00 mV
SCX150DNC
0 psid to 150 psid 150 psid 0.6 mV/psi
85.00 mV 90.00 mV 95.00 mV
* Ordering information: Order model number.
GENERAL SPECIFICATIONS
Characteristic Description (Maximum Ratings) All Devices
Supply Voltage (VS) 20 Vdc
Common Mode Pressure 50 psig
Lead Soldering Temperature
(2 seconds to 4 seconds)
250 °C [482 °F]
ENVIRONMENTAL SPECIFICATIONS
Characteristic Description (Maximum Ratings) All Devices
Compensated Operating Temperature 0 °C to 70 °C [32 °F to 158 °F]
Operating Temperature -40 °C to 85 °C [-40 °F to 185 °F]
Storage Temperature -55 °C to 125 °C [-67 °F to 257 °F]
Humidity Limits 0 % RH to 100 % RH
ACCURACY
Model Accuracy
SCX01 through SCX150 Calibrated for span to within ±1 % (Highest accuracy)
SCX01_C through SCX150_C Calibrated for span to within ±5 % (Fine adjustments of zero
and span can be provided in external circuitry)
2 Honeywell Sensing and Control
Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
SCX Serie
s
SCX PERFORMANCE CHARACTERISTICS
(3)
Characteristic Min. Typ. Max. Unit
Zero Pressure Offset
(4)
-300 0.0 300 Microvolt
Combined Pressure Non-Linearity and Pressure Hysteresis
(5)
– ±0.1 ±0.5 % FSO
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F]
(6)
– ±0.2 ±0.1 % FSO
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]
(6)
– ±100 ±500 Microvolt
Repeatability
(7)
– ±0.2 ±0.5 % FSO
Input Resistance
(8)
– 4.0 kOhm
Output Resistance
(9)
– 4.0 kOhm
Common Mode Voltage
(10)
5.8 6.0 6.2 Vdc
Response Time
(11)
– 100 Microsec.
Long Term Stability of Offset and Span
(12)
– ±0.1 – mV
SCX_C SERIES PERFORMANCE CHARACTERISTICS
(3)
Characteristic Min. Typ. Max Unit
Zero Pressure Offset
-1.0 0.0 ±1.0 mV
Combined Pressure Non-Linearity and Pressure Hysteresis
(5)
Models: SCX05DNC, SCX15ANC, and SCX15DNC,
Models: SCX01DNC, SCX30ANC, SCX30DNC, SCX100ANC, SCX100DNC,
SCX150ANC, and SCX150DNC
±0.1
±0.2
±1.0
±1.0
% FSO
% FSO
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F]
(6)
±0.4 ±2.0 % FSO
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]
(6)
– ±0.2 ±1.0 mV
Repeatability
(7)
– ±0.2 ±0.5 % FSO
Input Resistance
(8)
– 4.0 kOhm
Output Resistance
(9)
– 4.0 kOhm
Common Mode Voltage
(10)
5.7 6.0 6.3 Vdc
Response Time
(11)
– 100 Microsec.
Long Term Stability of Offset and Span
(12)
– ±0.1 mV
SPECIFICATION NOTES
Note 1: Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Full-Scale Span is ratiometric to the supply voltage.
Note 2: Maximum pressure above which causes permanent sensor failure.
Note 3: Reference Conditions: (Unless otherwise noted)
T
A
= 25°C, Supply V
S
= 12 Vdc, Common Mode Line pressure = 0 psig, Pressure applied to
Port B. For absolute devices only,
pressure is applied to Port A, and the output polarity is reversed.
Note 4: For models SCX15AN, SCX30AN, SCX100AN, and SCX150AN,
the Maximum zero pressure offset for absolute devices is 0 to ±500 Microvolt.
Note 5: Pressure Hysteresis – the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure.
Note 6: Maximum error band of the offset voltage and the error band of the span, relative to the 25 °C [77 °F] reading.
Note 7: Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 70 °C
[32 °F to 158 °F] after:
a) 1,000 temperature cycles, 0 °C to 70 °C [32 °F to 158 °F]
b) 1.5 million pressure cycles, 0 psi to Full-Scale Span.
Note 8: Input resistance is the resistance between pins 2 and 4.
Note 9: Output resistance is the resistance between pins 3 and 5.
Note 10: Common Mode voltage of the output arms (Pins 3 and 5) for V
S
=12 Vdc.
Note 11: Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
Note 12: Long term stability over a one-year period.
Honeywell Sensing and Control 3

SCX01DNC

Mfr. #:
Manufacturer:
Description:
Board Mount Pressure Sensors 20V 0 psid to 1 psid Gauge Transducer
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union