LY3100ALH Mechanical and electrical specifications
Doc ID 16570 Rev 1 5/13
2 Mechanical and electrical specifications
2.1 Mechanical characteristics
Vdd = 3 V, T = 25 °C unless otherwise noted
(a)
a. The product is factory calibrated at 3 V. The operational power supply range is specified in Table 4.
Table 3. Mechanical characteristics
Symbol Parameter Test condition Min. Typ.
(1)
Max. Unit
FS Measurement range ±1000 dps
So Sensitivity
(2)
1.1 mV/dps
SoDr
Sensitivity change vs.
temperature
Delta from 25°C 0.01 %/°C
Voff Zero-rate level
(3)
1.5 V
OffDr
Zero-rate level change
vs. temperature
Delta from 25°C 0.02 dps/°C
NL Non linearity Best fit straight line ±1 % FS
BW Bandwidth
(3)
140 Hz
Vst Self-test output change 100
(4)
mV
Rn Rate noise density 0.016 dps/√ Hz
Top
Operating temperature
range
-40 +85 °C
1. Typical specifications are not guaranteed.
2. Sensitivity and zero-rate offset are not ratiometric to supply voltage.
3. The product is capable of measuring angular rates extending from DC to the selected BW.
4. Self test typical absolute value.