TS432
Adjustable Precision Shunt Regulator
Document Number:
DS_P0000238
7
Version: F15
Typical Performance Characteristics
The areas under the curves represent conditions that may
cause the device to oscillate. For curves B, C, and D, R2
and V+ were adjusted to establish the initial V
KA
and I
KA
conditions with C
L
=0. V
BATT
and C
L
then were adjusted to
determine the ranges of stability.
Test Circuit for Curve A
Test Circuit for Curve B, C and D
Figure 17: Stability Boundary Condition
Test Circuit for Pulse Response, Ik=1mA
Figure 18: Pulse Response