■ Features
CXA-0359
CXA-0359 Specifications
(Please refer to each specification before use)
■ Applications
Dimming/Connector Type
● 2-output
●Applicable panel size*: 12 inches
●
With brightness control function (Pulse Wide Modulation mode).
●With shut down function.
●
With a sensing function for running out of lamp (alarm output).
●In the high-voltage generator(a terminal and a pattern),
an anti-dust measure by silicone application is taken.
●
Two stages of dimming range of a Hi mode and a Low mode is selectable.
(Notice) Applicable panel size becomes a standard.
Electrical Characteristics
Item Unit Symbol
Specifi cation Condition
min typ max Vin(V) Vrmt(V) Vbr(V)
Rbr(kΩ )
Hi/Low(V)
Ta(℃ )
RL(kΩ )
Remark
Output Current mArms
Iout
(Maximum dimmer)
6.5 7.0 7.5
120.6
52.5 - 5
-10 to +70
70
Voltage dimmer (*1)
6.5 7.0 7.5
120.6
5-105
-10 to +70
70
Volume dimmer (*1)
Iout
(Minimum dimmer)
2.6 3.5 4.0
120.6
50 - 5
-10 to +70
70
Voltage dimmer (*1)
2.6 3.5 4.0
120.6
5-05
-10 to +70
70
Volume dimmer (*1)
Input Current
AIin1 -0.81.0
120.6
52.510 5
-10 to +70
70
Remote ON
mA Iin2 - 1
120.6
02.510 5
-10 to +70
70
Remote OFF
Frequency
kHz Freq1 58 63 68
120.6
52.510 5
-10 to +70
70
Hz
Freq2 (Duty frequency)
310 340 370
120.6
505
-10 to +70
70
Open Circuit Voltage
Vrms Vopen 1800 - 2000
11.4min.
52.510 5
-10 to +70
∞ Open load
Alarm Signal V Vst
4.5 5.0 5.5
120.6
52.510 5
-10 to +70
∞
In case of lamp anomaly (*2)
-00.5
120.6
52.510 5
-10 to +70
70
On a normal operation (*2)
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
Other Specifications
Dimming Function
Yes
Operating Temperature
℃ -10 to +70
Storage Temperature
℃ -30 to +85
Operating Humidity Ratio
RH% 95Max
Safety Standard
ー
Weight g 23
Dimensions(WxDxH)
mm 120x25x8.5 (*3)
Fused Input Yes
Remote ON / OFF
Yes
Alarm Signal Function
Yes
Shutdown Function
Yes
Silicone Coating on
High Voltage Area
Yes
(*3) These dimensions are indicated the maximum only H. Others are typical values.
Item Unit Symbol
Specifi cation Condition
min typ max Vin(V) Vrmt(V) Vbr(V)
Rbr(kΩ )
Hi/Low(V)
Ta(℃ )
RL(kΩ )
Remark
Output Current mArms
Iout
(Maximum dimmer)
4.5 5 5.5
120.6
52.5 -
0 or open
-10 to +70
110
Voltage dimmer (*1)
4.5 5 5.5
120.6
5-10
0 or open
-10 to +70
110
Volume dimmer (*1)
Iout
(Minimum dimmer)
1.5 2.2 2.9
120.6
50 -
0 or open
-10 to +70
110
Voltage dimmer (*1)
1.5 2.2 2.9
120.6
5-0
0 or open
-10 to +70
110
Volume dimmer (*1)
Input Current
AIin1 -0.60.8
120.6
52.510
0 or open
-10 to +70
110
Remote ON
mA Iin2 - 1
120.6
02.510
0 or open
-10 to +70
110
Remote OFF
Frequency
kHz Freq1 58 63 68
120.6
52.510
0 or open
-10 to +70
110
Hz
Freq2 (Duty frequency)
310 340 370
120.6
50
0 or open
-10 to +70
110
Open Circuit Voltage
Vrms Vopen 1600 - 1800
11.4min.
52.510
0 or open
-10 to +70
∞ Open load
Alarm Signal V Vst
4.5 5.0 5.5
120.6
52.510
0 or open
-10 to +70
∞
In case of lamp anomaly (*2)
-00.5
120.6
52.510
0 or open
-10 to +70
110
On a normal operation (*2)
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
Low-mode
High-mode
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■
Conformity to RoHs Directive
001-01/20080228/etl_cxa_0359
All specifications are subject to change without notice.
1